The planned energy-efficient retrofitting of a residential building in Bologna, North-Center Italy is presented. The building is a detached house with an unheated basement, three floors with 2 apartments each, and an unheated attic. The total heated floor area is 281.9 m2. The external wall is made of solid brick masonry and most windows are single glazed; no thermal insulation is present. Space heating is supplied by a gas boiler and radiators in the rooms. DHW is supplied by single-apartment electric boilers in 5 apartments and by a gas boiler in one apartment. Lighting is obtained by incandescent lamps. The proposed retrofitting includes: external thermal insulation of the vertical walls by calcium silicate hydrates and loft insulation by mineral wool; replacement of windows; installation of a multifunction air-to-water heat pump for heating, cooling and DHW; replacement of the radiators by new heat exchangers; LED lighting; installation of PV panels. The building has been simulated by TRNSYS 17, and the heat pump has been simulated by own MATLAB codes. The retrofitting will reduce the total annual use of primary energy (excluding appliances) from 332.5 to 44.8 kWh/m2, and will yield an important improvement of thermal comfort.

Zanchini, E., Naldi, C., Lazzari, S., Morini, G.L. (2015). Planned energy-efficient retrofitting of a residential building in Italy. FUTURE CITIES AND ENVIRONMENT, 1(1), 1-19 [10.1186/s40984-015-0004-9].

Planned energy-efficient retrofitting of a residential building in Italy

ZANCHINI, ENZO;NALDI, CLAUDIA;MORINI, GIAN LUCA
2015

Abstract

The planned energy-efficient retrofitting of a residential building in Bologna, North-Center Italy is presented. The building is a detached house with an unheated basement, three floors with 2 apartments each, and an unheated attic. The total heated floor area is 281.9 m2. The external wall is made of solid brick masonry and most windows are single glazed; no thermal insulation is present. Space heating is supplied by a gas boiler and radiators in the rooms. DHW is supplied by single-apartment electric boilers in 5 apartments and by a gas boiler in one apartment. Lighting is obtained by incandescent lamps. The proposed retrofitting includes: external thermal insulation of the vertical walls by calcium silicate hydrates and loft insulation by mineral wool; replacement of windows; installation of a multifunction air-to-water heat pump for heating, cooling and DHW; replacement of the radiators by new heat exchangers; LED lighting; installation of PV panels. The building has been simulated by TRNSYS 17, and the heat pump has been simulated by own MATLAB codes. The retrofitting will reduce the total annual use of primary energy (excluding appliances) from 332.5 to 44.8 kWh/m2, and will yield an important improvement of thermal comfort.
2015
Zanchini, E., Naldi, C., Lazzari, S., Morini, G.L. (2015). Planned energy-efficient retrofitting of a residential building in Italy. FUTURE CITIES AND ENVIRONMENT, 1(1), 1-19 [10.1186/s40984-015-0004-9].
Zanchini, Enzo; Naldi, Claudia; Lazzari, Stefano; Morini, Gian Luca
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/575836
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact