A sample of 24 patients with varied morphologic defects were treated with 34 titanium meshes and particulate bone and rehabilitated at least 8 to 9 months thereafter with the placement of 88 implants. Of the 34 meshes, 4 had to be removed before implant placement (11.76% total failure) and 20 were exposed due to soft tissue dehiscence (58.82% of complications): 4 (11.77%) prematurely (within 4 to 6 weeks) and 16 (47.05%) delayed (after 4 to 6 weeks), with no compromise in implant placement. None of the 88 implants was lost (100% implant survival), and 15 demonstrated increased bone loss, yielding a cumulative implant success rate of 82.9%. This technique appears useful in treating extended and morphologically varied alveolar defects.

Lizio, G., Mazzone, N., Corinaldesi, G., Marchetti, C. (2016). Reconstruction of extended and morphologically varied alveolar ridge defects with the titanium mesh technique: Clinical and dental implants outcomes. THE INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 36(5), 689-697 [10.11607/prd.2447].

Reconstruction of extended and morphologically varied alveolar ridge defects with the titanium mesh technique: Clinical and dental implants outcomes

LIZIO, GIUSEPPE;CORINALDESI, GIUSEPPE;MARCHETTI, CLAUDIO
2016

Abstract

A sample of 24 patients with varied morphologic defects were treated with 34 titanium meshes and particulate bone and rehabilitated at least 8 to 9 months thereafter with the placement of 88 implants. Of the 34 meshes, 4 had to be removed before implant placement (11.76% total failure) and 20 were exposed due to soft tissue dehiscence (58.82% of complications): 4 (11.77%) prematurely (within 4 to 6 weeks) and 16 (47.05%) delayed (after 4 to 6 weeks), with no compromise in implant placement. None of the 88 implants was lost (100% implant survival), and 15 demonstrated increased bone loss, yielding a cumulative implant success rate of 82.9%. This technique appears useful in treating extended and morphologically varied alveolar defects.
2016
Lizio, G., Mazzone, N., Corinaldesi, G., Marchetti, C. (2016). Reconstruction of extended and morphologically varied alveolar ridge defects with the titanium mesh technique: Clinical and dental implants outcomes. THE INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 36(5), 689-697 [10.11607/prd.2447].
Lizio, Giuseppe; Mazzone, Noemi; Corinaldesi, Giuseppe; Marchetti, Claudio
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/564445
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 14
social impact