BACKGROUND: Studies of aortic aneurysm patients have shown that the risk of rupture increases with aortic size. However, few studies of acute aortic dissection patients and aortic size exist. We used data from our registry of acute aortic dissection patients to better understand the relationship between aortic diameter and type A dissection. METHODS AND RESULTS: We examined 591 type A dissection patients enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2005 (mean age, 60.8 years). Maximum aortic diameters averaged 5.3 cm; 349 (59%) patients had aortic diameters <5.5 cm and 229 (40%) patients had aortic diameters <5.0 cm. Independent predictors of dissection at smaller diameters (<5.5 cm) included a history of hypertension (odds ratio, 2.17; 95% confidence interval, 1.03 to 4.57; P=0.04), radiating pain (odds ratio, 2.08; 95% confidence interval, 1.08 to 4.0; P=0.03), and increasing age (odds ratio, 1.03; 95% confidence interval, 1.00 to 1.05; P=0.03). Marfan syndrome patients were more likely to dissect at larger diameters (odds ratio, 14.3; 95% confidence interval, 2.7 to 100; P=0.002). Mortality (27% of patients) was not related to aortic size. CONCLUSIONS: The majority of patients with acute type A acute aortic dissection present with aortic diameters <5.5 cm and thus do not fall within current guidelines for elective aneurysm surgery. Methods other than size measurement of the ascending aorta are needed to identify patients at risk for dissection.

Aortic diameter >or = 5.5 cm is not a good predictor of type A aortic dissection: observations from the International Registry of Acute Aortic Dissection (IRAD) / Pape LA, Tsai TT, Isselbacher EM, Oh JK, O'gara PT, Evangelista A, Fattori R, Meinhardt G, Trimarchi S, Bossone E, Suzuki T, Cooper JV, Froehlich JB, Nienaber CA, Eagle KA; International Registry of Acute Aortic Dissection (IRAD). - In: CIRCULATION. - ISSN 0009-7322. - STAMPA. - 116(10):(2007), pp. 1120-1127.

Aortic diameter >or = 5.5 cm is not a good predictor of type A aortic dissection: observations from the International Registry of Acute Aortic Dissection (IRAD).

FATTORI, ROSSELLA;
2007

Abstract

BACKGROUND: Studies of aortic aneurysm patients have shown that the risk of rupture increases with aortic size. However, few studies of acute aortic dissection patients and aortic size exist. We used data from our registry of acute aortic dissection patients to better understand the relationship between aortic diameter and type A dissection. METHODS AND RESULTS: We examined 591 type A dissection patients enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2005 (mean age, 60.8 years). Maximum aortic diameters averaged 5.3 cm; 349 (59%) patients had aortic diameters <5.5 cm and 229 (40%) patients had aortic diameters <5.0 cm. Independent predictors of dissection at smaller diameters (<5.5 cm) included a history of hypertension (odds ratio, 2.17; 95% confidence interval, 1.03 to 4.57; P=0.04), radiating pain (odds ratio, 2.08; 95% confidence interval, 1.08 to 4.0; P=0.03), and increasing age (odds ratio, 1.03; 95% confidence interval, 1.00 to 1.05; P=0.03). Marfan syndrome patients were more likely to dissect at larger diameters (odds ratio, 14.3; 95% confidence interval, 2.7 to 100; P=0.002). Mortality (27% of patients) was not related to aortic size. CONCLUSIONS: The majority of patients with acute type A acute aortic dissection present with aortic diameters <5.5 cm and thus do not fall within current guidelines for elective aneurysm surgery. Methods other than size measurement of the ascending aorta are needed to identify patients at risk for dissection.
2007
Aortic diameter >or = 5.5 cm is not a good predictor of type A aortic dissection: observations from the International Registry of Acute Aortic Dissection (IRAD) / Pape LA, Tsai TT, Isselbacher EM, Oh JK, O'gara PT, Evangelista A, Fattori R, Meinhardt G, Trimarchi S, Bossone E, Suzuki T, Cooper JV, Froehlich JB, Nienaber CA, Eagle KA; International Registry of Acute Aortic Dissection (IRAD). - In: CIRCULATION. - ISSN 0009-7322. - STAMPA. - 116(10):(2007), pp. 1120-1127.
Pape LA, Tsai TT, Isselbacher EM, Oh JK, O'gara PT, Evangelista A, Fattori R, Meinhardt G, Trimarchi S, Bossone E, Suzuki T, Cooper JV, Froehlich JB, Nienaber CA, Eagle KA; International Registry of Acute Aortic Dissection (IRAD)
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/56381
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 569
social impact