Background: Cancer multicellular spheroids are commonly used as 3D tumour models for testing drugs and radiotherapy treatments. The volume plays a key role in analysis of the results. Several methods have been proposed in the literature to compute the spheroid's volume from one 2D microscopy image (i.e. a single projection). However, the literature lacks reviews summarizing the different methods available. Furthermore, there are no well-established approaches by which to compare the different methods and determine the best one. Objective: In this work we: (a) revise the existing single-image based methods used to estimate the volume of multicellular spheroids, also providing different implementations for classical spherical and ellipsoidal pre-defined models; (b) present an upgrade of a volume estimation software recently proposed, Reconstruction and Visualization from a Single Projection (ReViSP), just validated by using four real spheroids imaged in 3D with a light-sheet microscope; (c) propose a quality assessing approach for single-image based methods, relying on 3D home-made macroscopic synthetic models mimicking the shapes of real multicellular spheroids. Results: Seven image-based methods used to estimate the volume of spheroids were compared using six 3D home-made synthetic models. First, the material used to make the synthetic models was characterized to estimate its density. Then, the ground-truth volume of the 3D models was measured by simply weighing them. The volume instances estimated by the different methods were compared with ground truth. ReViSP attained the best result three times out of six and on average.
Filippo, P., Anna, T., Alessandro, B. (2016). Single-image based methods used for non-invasive volume estimation of cancer spheroids: a practical assessing approach based on entry-level equipment. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 135, 51-60 [10.1016/j.cmpb.2016.07.024].
Single-image based methods used for non-invasive volume estimation of cancer spheroids: a practical assessing approach based on entry-level equipment
PICCININI, FILIPPO;TESEI, ANNA;BEVILACQUA, ALESSANDRO
2016
Abstract
Background: Cancer multicellular spheroids are commonly used as 3D tumour models for testing drugs and radiotherapy treatments. The volume plays a key role in analysis of the results. Several methods have been proposed in the literature to compute the spheroid's volume from one 2D microscopy image (i.e. a single projection). However, the literature lacks reviews summarizing the different methods available. Furthermore, there are no well-established approaches by which to compare the different methods and determine the best one. Objective: In this work we: (a) revise the existing single-image based methods used to estimate the volume of multicellular spheroids, also providing different implementations for classical spherical and ellipsoidal pre-defined models; (b) present an upgrade of a volume estimation software recently proposed, Reconstruction and Visualization from a Single Projection (ReViSP), just validated by using four real spheroids imaged in 3D with a light-sheet microscope; (c) propose a quality assessing approach for single-image based methods, relying on 3D home-made macroscopic synthetic models mimicking the shapes of real multicellular spheroids. Results: Seven image-based methods used to estimate the volume of spheroids were compared using six 3D home-made synthetic models. First, the material used to make the synthetic models was characterized to estimate its density. Then, the ground-truth volume of the 3D models was measured by simply weighing them. The volume instances estimated by the different methods were compared with ground truth. ReViSP attained the best result three times out of six and on average.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.