The paper presents an analysis of the current distribution and electromagnetic losses in the NAFASSY magnet carried out with the THELMA code, thanks to a brand-new thermal module coupled with the pre-existing electromagnetic module. The non-linear thermal and electrical properties of both superconducting and copper strands, depending on the local temperature, current density and magnetic field, are taken into account. The model analyses a single turn of the magnet, located in the highest field zone, focusing on the current distribution in the cable, the coupling AC and DC losses during ramped waveforms. The results are then extrapolated to estimate the behaviour of the overall magnet. A description of the models is given, together with a parametric analysis of different boundary conditions and cable discretizations. The analysis shows that, in nominal working conditions, no thermal instability should take place. However, local current redistribution among the strands may occur, mainly driven by the interstrand contact pattern, the local magnetic field and the strand current density.

Coupled thermal and electromagnetic analysis of the NAFASSY magnet / Manfreda, Giulio; Bellina, Fabrizio; Corato, Valentina; Della Corte, Antonio; Ribani, Pierluigi. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - STAMPA. - 25:3(2015), pp. 6949112.1-6949112.6. [10.1109/TASC.2014.2368251]

Coupled thermal and electromagnetic analysis of the NAFASSY magnet

RIBANI, PIER LUIGI
2015

Abstract

The paper presents an analysis of the current distribution and electromagnetic losses in the NAFASSY magnet carried out with the THELMA code, thanks to a brand-new thermal module coupled with the pre-existing electromagnetic module. The non-linear thermal and electrical properties of both superconducting and copper strands, depending on the local temperature, current density and magnetic field, are taken into account. The model analyses a single turn of the magnet, located in the highest field zone, focusing on the current distribution in the cable, the coupling AC and DC losses during ramped waveforms. The results are then extrapolated to estimate the behaviour of the overall magnet. A description of the models is given, together with a parametric analysis of different boundary conditions and cable discretizations. The analysis shows that, in nominal working conditions, no thermal instability should take place. However, local current redistribution among the strands may occur, mainly driven by the interstrand contact pattern, the local magnetic field and the strand current density.
2015
Coupled thermal and electromagnetic analysis of the NAFASSY magnet / Manfreda, Giulio; Bellina, Fabrizio; Corato, Valentina; Della Corte, Antonio; Ribani, Pierluigi. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - STAMPA. - 25:3(2015), pp. 6949112.1-6949112.6. [10.1109/TASC.2014.2368251]
Manfreda, Giulio; Bellina, Fabrizio; Corato, Valentina; Della Corte, Antonio; Ribani, Pierluigi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/555410
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact