A speed control scheme is proposed for a 3-phase induction motor that uses an open-ended stator winding fed by a dual inverter system with a floating bridge. The floating bridge has a voltage boosting function that extends the constant power high-speed range of the induction machine and operates the main inverter bridge at unity power factor. The proposed control scheme coordinates the two inverters that supply the motor, regulates the dc-link voltage of the floating bridge and boosts the machine terminal voltage at high speed. Simulation results are used to clarify the motor-drive torque capability in the high speed region. Experimental results show that a significant power improvement is achievable in the field weakening region.

Control of an open-ended induction machine using a dual inverter system with a floating capacitor bridge / Mengoni, M.; Tani, A.; Zarri, L.; Rizzoli, G.; Serra, G.; Casadei, D.. - STAMPA. - (2015), pp. 7310347.4872-7310347.4879. (Intervento presentato al convegno 7th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2015 tenutosi a Palais des Congres de Montreal (Montreal Convention Centre), can nel 2015) [10.1109/ECCE.2015.7310347].

Control of an open-ended induction machine using a dual inverter system with a floating capacitor bridge

MENGONI, MICHELE;TANI, ANGELO;ZARRI, LUCA;RIZZOLI, GABRIELE;SERRA, GIOVANNI;CASADEI, DOMENICO
2015

Abstract

A speed control scheme is proposed for a 3-phase induction motor that uses an open-ended stator winding fed by a dual inverter system with a floating bridge. The floating bridge has a voltage boosting function that extends the constant power high-speed range of the induction machine and operates the main inverter bridge at unity power factor. The proposed control scheme coordinates the two inverters that supply the motor, regulates the dc-link voltage of the floating bridge and boosts the machine terminal voltage at high speed. Simulation results are used to clarify the motor-drive torque capability in the high speed region. Experimental results show that a significant power improvement is achievable in the field weakening region.
2015
2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015
4872
4879
Control of an open-ended induction machine using a dual inverter system with a floating capacitor bridge / Mengoni, M.; Tani, A.; Zarri, L.; Rizzoli, G.; Serra, G.; Casadei, D.. - STAMPA. - (2015), pp. 7310347.4872-7310347.4879. (Intervento presentato al convegno 7th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2015 tenutosi a Palais des Congres de Montreal (Montreal Convention Centre), can nel 2015) [10.1109/ECCE.2015.7310347].
Mengoni, M.; Tani, A.; Zarri, L.; Rizzoli, G.; Serra, G.; Casadei, D.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/553594
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact