The present work aims to evaluate the mobility of the polyethylene bearing in 25 patients implanted with a mobile-bearing PCL-retaining TKR (Interax ISA, Striker Howmedica) under in vivo, weight-bearing conditions over 3 years' follow-up. We compared the bearing motion in response to specific tests in two consecutive follow-ups with Roentgen Stereophotogrammetric Analysis (RSA). Results showed that polyethylene continued to displace on the tibial baseplate over time: longitudinal rotations and medio-lateral translations tended to increase at the second follow-up (mean increases 0.7 ± 2.5° and 0.34 ± 1.08 mm, respectively), while sagittal translations did not show any relevant change. Longitudinal rotations and AP translations were preserved when present at both follow-ups. Nevertheless, no statistical evidence of repeatable pattern of motion was found, since bearings frequently reversed their pattern of motion between the two follow-ups. The unconstrained polyethylene mobility resulted in an unrepeatable, erratic pattern of bearing motion intra-patient and over time. The changes in knee motion were found not to affect the clinical results over the first 3 years of follow-up. As in a fixed-bearing design, mobile-bearing design was not able to reproduce normal knee kinematics. © 2006 Elsevier B.V. All rights reserved.

Russo, A., Montagna, L., Bragonzoni, L., Visani, A., Marcacci, M. (2006). Changes in knee motion over the first 3 years with a mobile-bearing prosthesis. THE KNEE, 13(4), 301-306 [10.1016/j.knee.2006.04.007].

Changes in knee motion over the first 3 years with a mobile-bearing prosthesis

BRAGONZONI, LAURA;MARCACCI, MAURILIO
2006

Abstract

The present work aims to evaluate the mobility of the polyethylene bearing in 25 patients implanted with a mobile-bearing PCL-retaining TKR (Interax ISA, Striker Howmedica) under in vivo, weight-bearing conditions over 3 years' follow-up. We compared the bearing motion in response to specific tests in two consecutive follow-ups with Roentgen Stereophotogrammetric Analysis (RSA). Results showed that polyethylene continued to displace on the tibial baseplate over time: longitudinal rotations and medio-lateral translations tended to increase at the second follow-up (mean increases 0.7 ± 2.5° and 0.34 ± 1.08 mm, respectively), while sagittal translations did not show any relevant change. Longitudinal rotations and AP translations were preserved when present at both follow-ups. Nevertheless, no statistical evidence of repeatable pattern of motion was found, since bearings frequently reversed their pattern of motion between the two follow-ups. The unconstrained polyethylene mobility resulted in an unrepeatable, erratic pattern of bearing motion intra-patient and over time. The changes in knee motion were found not to affect the clinical results over the first 3 years of follow-up. As in a fixed-bearing design, mobile-bearing design was not able to reproduce normal knee kinematics. © 2006 Elsevier B.V. All rights reserved.
2006
Russo, A., Montagna, L., Bragonzoni, L., Visani, A., Marcacci, M. (2006). Changes in knee motion over the first 3 years with a mobile-bearing prosthesis. THE KNEE, 13(4), 301-306 [10.1016/j.knee.2006.04.007].
Russo, Alessandro; Montagna, Luisa; Bragonzoni, Laura; Visani, Andrea; Marcacci, Maurilio
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/551562
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact