Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n-TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of κT = 5 - 100 keV, and their astrophysical implications were investigated.
Žugec, P., Barbagallo, M., Colonna, N., Bosnar, D., Altstadt, S., Andrzejewski, J., et al. (2015). Experimental neutron capture data of 58Ni from the CERN n-TOF facility. EPJ WEB OF CONFERENCES, 93, 02009-02013 [10.1051/epjconf/20159302009].
Experimental neutron capture data of 58Ni from the CERN n-TOF facility
Žugec, P.;Barbagallo, M.;Colonna, N.;Bosnar, D.;Altstadt, S.;Andrzejewski, J.;Audouin, L.;Bécares, V.;Bečvář, F.;Belloni, F.;Berthoumieux, E.;Billowes, J.;Boccone, V.;Brugger, M.;Calviani, M.;Calviño, F.;Cano Ott, D.;Carrapiço, C.;Cerutti, F.;Chiaveri, E.;Chin, M.;Cortés, G.;Cortés Giraldo, M. A.;Diakaki, M.;Domingo Pardo, C.;Dressler, R.;Duran, I.;Dzysiuk, N.;Eleftheriadis, C.;Ferrari, A.;Fraval, K.;Ganesan, S.;García, A. R.;Giubrone, G.;Gómez Hornillos, M. B.;Gonçalves, I. F.;González Romero, E.;Griesmayer, E.;Guerrero, C.;Gunsing, F.;Gurusamy, P.;Heinitz, S.;Jenkins, D. G.;Jericha, E.;Kadi, Y.;Käppeler, F.;Karadimos, D.;Kivel, N.;Koehler, P.;Kokkoris, M.;Krtička, M.;Kroll, J.;Langer, C.;Lederer, C.;Leeb, H.;Leong, L. S.;Lo Meo, S.;Losito, R.;Manousos, A.;Marganiec, J.;Martínez, T.;MASSIMI, CRISTIAN;Mastinu, P. F.;Mastromarco, M.;Meaze, M.;Mendoza, E.;Mengoni, A.;Milazzo, P. M.;Mingrone, F.;Mirea, M.;Mondalaers, W.;Paradela, C.;Pavlik, A.;Perkowski, J.;Pignatari, M.;Plompen, A.;Praena, J.;Quesada, J. M.;Rauscher, T.;Reifarth, R.;Riegov, A.;Roman, F.;Rubbia, C.;Sarmento, R.;Saxena, A.;Schillebeeckx, P.;Schmidt, S.;Schumann, D.;Tagliente, G.;Tain, J. L.;Tarrío, D.;Tassan Got, L.;Tsinganis, A.;Valenta, S.;VANNINI, GIANNI;Variale, V.;Vaz, P.;Ventura, A.;Versaci, R.;Vermeulen, M. J.;Vlachoudis, V.;Vlastou, R.;Wallner, A.;Ware, T.;Weigand, M.;Weiß, C.;Wright, T.
2015
Abstract
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n-TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of κT = 5 - 100 keV, and their astrophysical implications were investigated.
Žugec, P., Barbagallo, M., Colonna, N., Bosnar, D., Altstadt, S., Andrzejewski, J., et al. (2015). Experimental neutron capture data of 58Ni from the CERN n-TOF facility. EPJ WEB OF CONFERENCES, 93, 02009-02013 [10.1051/epjconf/20159302009].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/550089
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.