Background and Objectives: Failures of endoscopic ultrasound (EUS) imaging of the head of the pancreas (HOP) and the common bile duct (CBD) have been reported in up to 50% of patients with status postsurgery (e.g., Billroth II and Roux-en-Y). This is attributable to inability to intubate the afferent limb or the duodenum. Recently, a forward-view (FV) echoendoscope has become available. The frontal endoscopic and ultrasound fi eld of view theoretically allow easier manipulation throughout the gastrointestinal tract compared to the traditional echoendoscopes. The aim of our study was to evaluate the safety and performance of the FV echoendoscope for the investigation of the biliary tree and the pancreas, including fi ne-needle aspiration (FNA), in patients with surgically altered upper gastrointestinal anatomy. Patients and Methods: This was a retrospective evaluation of a prospectively maintained database. All EUS procedures were performed at our institution by one experienced endosonographer from March to September 2009 under conscious sedation. The FV echoendoscope was used for all procedures. Results: Twenty-fi ve (25) out of 37 presented status post-Billroth II and 12 out of 37 with status post-Roux-en-Y surgery. Overall, HOP and CBD were adequately visualized in 28 out of 37 (75.7%). All the failures occurred in the Roux-en-Y patients. EUS-FNA was successfully performed in 16 patients. No adverse events were observed. Conclusions: The FV echoendoscope proved to be safe and effective in reaching the periampullary area in patients with previous Billroth II, allowing complete exploration of the HOP and the CBD and performance of EUS-FNA. However, FV EUS was unsuccessful in the majority of patients with Roux-en-Y, which still remains a challenging condition.

Fusaroli, P., Serrani, M., Lisotti, A., D'Ercole, M.C., Ceroni, L., Caletti, G. (2015). Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery. ENDOSCOPIC ULTRASOUND, 4(4), 336-341 [10.4103/2303-9027.170427].

Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery

FUSAROLI, PIETRO;SERRANI, MARTA;LISOTTI, ANDREA;CERONI, LIZA;CALETTI, GIANCARLO
2015

Abstract

Background and Objectives: Failures of endoscopic ultrasound (EUS) imaging of the head of the pancreas (HOP) and the common bile duct (CBD) have been reported in up to 50% of patients with status postsurgery (e.g., Billroth II and Roux-en-Y). This is attributable to inability to intubate the afferent limb or the duodenum. Recently, a forward-view (FV) echoendoscope has become available. The frontal endoscopic and ultrasound fi eld of view theoretically allow easier manipulation throughout the gastrointestinal tract compared to the traditional echoendoscopes. The aim of our study was to evaluate the safety and performance of the FV echoendoscope for the investigation of the biliary tree and the pancreas, including fi ne-needle aspiration (FNA), in patients with surgically altered upper gastrointestinal anatomy. Patients and Methods: This was a retrospective evaluation of a prospectively maintained database. All EUS procedures were performed at our institution by one experienced endosonographer from March to September 2009 under conscious sedation. The FV echoendoscope was used for all procedures. Results: Twenty-fi ve (25) out of 37 presented status post-Billroth II and 12 out of 37 with status post-Roux-en-Y surgery. Overall, HOP and CBD were adequately visualized in 28 out of 37 (75.7%). All the failures occurred in the Roux-en-Y patients. EUS-FNA was successfully performed in 16 patients. No adverse events were observed. Conclusions: The FV echoendoscope proved to be safe and effective in reaching the periampullary area in patients with previous Billroth II, allowing complete exploration of the HOP and the CBD and performance of EUS-FNA. However, FV EUS was unsuccessful in the majority of patients with Roux-en-Y, which still remains a challenging condition.
2015
Fusaroli, P., Serrani, M., Lisotti, A., D'Ercole, M.C., Ceroni, L., Caletti, G. (2015). Performance of the forward-view echoendoscope for pancreaticobiliary examination in patients with status post-upper gastrointestinal surgery. ENDOSCOPIC ULTRASOUND, 4(4), 336-341 [10.4103/2303-9027.170427].
Fusaroli, Pietro; Serrani, Marta; Lisotti, Andrea; D'Ercole, Maria Cristina; Ceroni, Liza; Caletti, Giancarlo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/547673
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 34
social impact