Background: This study describes the pattern of ultrasonographic contrast enhancement of the pancreatic body and left lobe using a second-generation commercial contrast medium (Sonovue) in 10 clinically healthy cats. Results: Following contrast medium administration, microbubbles were observed within the splenic artery. This was followed by an inflow of contrast medium into the pancreatic capillary beds, providing a uniformly contrast-enhanced pancreas at peak intensity (PI). At the time of PI, a replenishment of the splenic and portal veins started and increased progressively during the wash-out phase. During the wash-out phase, the echogenicity of the pancreatic parenchyma decreased progressively. Perfusion parameters included arrival time (4.69 ± 1.26 s), time to peak from injection (7.52 ± 1.88 s), time to peak from initial rise (2.84 ± 0.88 s), peak intensity (6.58 ± 2.66 a.u.), and wash-in rate (2.11 ± 1.79 a.u./s). Conclusions: This perfusion pattern of normal pancreatic parenchyma may be useful for characterising cats with exocrine pancreatic disorders.

Diana, A., Linta, N., Cipone, M., Fedone, V., Steiner, J.M., Fracassi, F., et al. (2015). Contrast-enhanced ultrasonography of the pancreas in healthy cats. BMC VETERINARY RESEARCH, 11, 1-7 [10.1186/s12917-015-0380-2].

Contrast-enhanced ultrasonography of the pancreas in healthy cats

DIANA, ALESSIA;LINTA, NIKOLINA;CIPONE, MARIO;FRACASSI, FEDERICO;GRANDIS, ANNAMARIA;BARON TOALDO, MARCO
2015

Abstract

Background: This study describes the pattern of ultrasonographic contrast enhancement of the pancreatic body and left lobe using a second-generation commercial contrast medium (Sonovue) in 10 clinically healthy cats. Results: Following contrast medium administration, microbubbles were observed within the splenic artery. This was followed by an inflow of contrast medium into the pancreatic capillary beds, providing a uniformly contrast-enhanced pancreas at peak intensity (PI). At the time of PI, a replenishment of the splenic and portal veins started and increased progressively during the wash-out phase. During the wash-out phase, the echogenicity of the pancreatic parenchyma decreased progressively. Perfusion parameters included arrival time (4.69 ± 1.26 s), time to peak from injection (7.52 ± 1.88 s), time to peak from initial rise (2.84 ± 0.88 s), peak intensity (6.58 ± 2.66 a.u.), and wash-in rate (2.11 ± 1.79 a.u./s). Conclusions: This perfusion pattern of normal pancreatic parenchyma may be useful for characterising cats with exocrine pancreatic disorders.
2015
Diana, A., Linta, N., Cipone, M., Fedone, V., Steiner, J.M., Fracassi, F., et al. (2015). Contrast-enhanced ultrasonography of the pancreas in healthy cats. BMC VETERINARY RESEARCH, 11, 1-7 [10.1186/s12917-015-0380-2].
Diana, Alessia; Linta, Nikolina; Cipone, Mario; Fedone, Valeria; Steiner, Joerg M; Fracassi, Federico; Grandis, Annamaria; Barontoaldo, Marco
File in questo prodotto:
File Dimensione Formato  
CEUS PANCREAS _Article_380.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 3.43 MB
Formato Adobe PDF
3.43 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/546135
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 11
social impact