The CUORE experiment will search for neutrinoless double-beta decay of
$^130$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
Cuore, C., Alduino, C., Alfonso, K., Artusa, D.R., Avignone III, F.T., Azzolini, O., et al. (2016). CUORE-0 detector: design, construction and operation. JOURNAL OF INSTRUMENTATION, 11, 1-35 [10.1088/1748-0221/11/07/P07009].
CUORE-0 detector: design, construction and operation
Cuore, Collaboration;Alduino, C.;Alfonso, K.;Artusa, D. R.;Avignone III, F. T.;Azzolini, O.;Balata, M.;Banks, T. I.;Bari, G.;Beeman, J. W.;Bellini, F.;Bersani, A.;Biare, D.;Biassoni, M.;Bragazzi, F.;Brofferio, C.;Buccheri, A.;Bucci, C.;Bulfon, C.;Caminata, A.;Canonica, L.;Cao, X. G.;Capelli, S.;Capodiferro, M.;Cappelli, L.;Carbone, L.;Cardani, L.;Cariello, M.;Carniti, P.;Casali, N.;Cassina, L.;Cereseto, R.;Ceruti, G.;Chiarini, A.;Chiesa, D.;Chott, N.;Clemenza, M.;Conventi, D.;Copello, S.;Cosmelli, C.;Cremonesi, O.;Creswick, R. J.;Cushman, J. S.;Dafinei, I.;Davis, C. J.;Dell'Oro, S.;DENINNO, MARIA MADDALENA;Di Domizio, S.;Di Vacri, M. L.;Dipaolo, L.;Drobizhev, A.;Erme, G.;Fang, D. Q.;Faverzani, M.;Fernandes, G.;Ferri, E.;Ferroni, F.;Fiorini, E.;Freedman, S. J.;Fujikawa, B. K.;Gaigher, R.;Giachero, A.;Gironi, L.;Giuliani, A.;Gladstone, L.;Gorla, P.;Gotti, C.;Guetti, M.;Gutierrez, T. D.;Haller, E. E.;Han, K.;Hansen, E.;Heeger, K. M.;Hennings Yeomans, R.;Hickerson, K. P.;Huang, H. Z.;Iannone, M.;Ioannucci, L.;Kadel, R.;Keppel, G.;Kolomensky, Y.u. G.;Leder, A.;Lim, K. E.;Liu, X.;Ma, Y. G.;Maino, M.;Marini, L.;Martinez, M.;Maruyama, R. H.;Mazza, R.;Mei, Y.;Meijer, S.;Michinelli, R.;Miller, D.;MOGGI, NICCOLO';Morganti, S.;Mosteiro, P. J.;Nastasi, M.;Nisi, S.;Nones, C.;Norman, E. B.;Nucciotti, A.;O'Donnell, T.;Orio, F.;Orlandi, D.;Ouellet, J. L.;Pagliarone, C. E.;Pallavicini, M.;Palmieri, V.;Pancaldi, G.;Pattavina, L.;Pavan, M.;Pedrotta, R.;Pelosi, A.;Perego, M.;Pessina, G.;Pettinacci, V.;Piperno, G.;Pirro, S.;Pozzi, S.;Previtali, E.;Rosenfeld, C.;Rusconi, C.;Sala, E.;Sangiorgio, S.;Santone, D.;Scielzo, N. D.;Singh, V.;Sisti, M.;Smith, A. R.;Stivanello, F.;Taffarello, L.;Tatananni, L.;Tenconi, M.;Terranova, F.;Tessaro, M.;Tomei, C.;Trentalange, S.;Ventura, G.;Vignati, M.;Wagaarachchi, S. L.;Wallig, J.;Wang, B. S.;Wang, H. W.;Wilson, J.;Winslow, L. A.;Wise, T.;Zanotti, L.;Zarra, C.;Zhang, G. Q.;Zhu, B. X.;Zimmermann, S.;ZUCCHELLI, STEFANO
2016
Abstract
The CUORE experiment will search for neutrinoless double-beta decay of
$^130$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
Cuore, C., Alduino, C., Alfonso, K., Artusa, D.R., Avignone III, F.T., Azzolini, O., et al. (2016). CUORE-0 detector: design, construction and operation. JOURNAL OF INSTRUMENTATION, 11, 1-35 [10.1088/1748-0221/11/07/P07009].
Cuore, Collaboration; Alduino, C.; Alfonso, K.; Artusa, D. R.; Avignone III, F. T.; Azzolini, O.; Balata, M.; Banks, T. I.; Bari, G.; Beeman, J. W.; B...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/540853
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
92
79
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.