PURPOSE: Starting from the hypothesis that a deep-dished highly congruent tibial insert in cruciate-retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6-month follow-up. METHODS: Twenty patients treated with cruciate-retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57-83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior-posterior and medio-lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF-36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores. RESULTS: Patellar tendon angle and anterior patellar translation significantly increased in post-operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre- and post-operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post-operative decrease (p < 0.0033) in the range of motion. CONCLUSIONS: The present study failed to demonstrate that deep-dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate-retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach. LEVEL OF EVIDENCE: Case series, Level IV.

Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation / Akkawi, Ibrahim; Colle, Francesca; Bruni, Danilo; Raspugli, Giovanni Francesco; Bignozzi, Simone; Zaffagnini, Stefano; Iacono, Francesco; Marcacci, Maurilio. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - 23:6(2015), pp. 2889.1622-2889.1630. [10.1007/s00167-014-2889-5]

Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation

BRUNI, DANILO;RASPUGLI, GIOVANNI FRANCESCO;ZAFFAGNINI, STEFANO;IACONO, FRANCESCO;MARCACCI, MAURILIO
2015

Abstract

PURPOSE: Starting from the hypothesis that a deep-dished highly congruent tibial insert in cruciate-retaining total knee arthroplasty would prevent the increase in patellar tendon angle and anterior patellar translation by reducing the paradoxical anterior femoral translation, the main purpose of the present study was to investigate the effect of this prosthesis design, and secondary to assess the clinical outcomes at 6-month follow-up. METHODS: Twenty patients treated with cruciate-retaining total knee arthroplasty with navigation technique were enrolled and prospectively followed up at 6 months. The median value of age was 71 years (57-83). Before and after surgery, the following parameters were calculated: patellar tendon angle, anterior-posterior and medio-lateral patellar translation, patellar height and range of motion. All patients were assessed with the SF-36 Physical Functioning and the Knee injury and Osteoarthritis Outcome Score ADL scores. RESULTS: Patellar tendon angle and anterior patellar translation significantly increased in post-operative conditions (p < 0.0001); a statistically significant medial patellar translation was found (p < 0.0001), while patellar height did not show any difference between pre- and post-operative conditions (n.s). A significant correlation was found between patellar tendon angle and anterior patellar translation and the clinical scores (p < 0.0417). There was a significant post-operative decrease (p < 0.0033) in the range of motion. CONCLUSIONS: The present study failed to demonstrate that deep-dished highly congruent tibial insert prevents the anterior translation of the patella in cruciate-retaining total knee arthroplasty, thus causing inferior clinical scores. It provided useful information about the biomechanical role of the patella in total knee arthroplasty, allowing to choose the most appropriate surgical approach. LEVEL OF EVIDENCE: Case series, Level IV.
2015
Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation / Akkawi, Ibrahim; Colle, Francesca; Bruni, Danilo; Raspugli, Giovanni Francesco; Bignozzi, Simone; Zaffagnini, Stefano; Iacono, Francesco; Marcacci, Maurilio. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - 23:6(2015), pp. 2889.1622-2889.1630. [10.1007/s00167-014-2889-5]
Akkawi, Ibrahim; Colle, Francesca; Bruni, Danilo; Raspugli, Giovanni Francesco; Bignozzi, Simone; Zaffagnini, Stefano; Iacono, Francesco; Marcacci, Maurilio
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/520762
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact