PURPOSE: Good clinical results have been demonstrated in numerous clinical studies using the collagen meniscus implant (CMI); however, the MRI behaviour of the scaffold, evaluated with Genovese score, is limited to a few cases series. The purpose was to evaluate, using the Genovese score, the MRI behaviour of the CMI at different follow-up periods and investigate possible differences in the behaviour of lateral and medial CMI. METHODS: A comprehensive search was performed on PubMed, Medline, CINAHL, Cochrane, Embase and Google Scholar databases using various combinations of the following keywords: "collagen meniscus implant" or "collagen meniscal implant". All the studies evaluating medial or lateral CMI using Genovese score for MRI were included in the systematic review. RESULTS: Six studies have been included in the systematic review, with no RCT's. The pooled number of patients involved in CMI surgery was 194 (83 % medial and 17 % lateral), with a mean age at surgery of 37.7 years. Concomitant procedures raged from 11 to 52 %. CMI morphology was grade 1 in 0, 2.7, 5.9, 0, 16.7 %, respectively, at 6 months, 1, 2, 5, 10 years. It was grade 2 in 12.5, 60.9, 60.3, 74.4, 75 %, respectively, at 6 months, 1, 2, 5, 10 years and grade 3 in 87.5, 36.4, 33.8, 25.6, 8.3 % at the same time points. CMI signal intensity was grade 1 in 80, 18.2, 25, 11.1, 22.2 %, respectively, at 6 months, 1, 2, 5, 10 years. It was grade 2 in 20, 78.2, 54.7, 55.6, 66.7 %, respectively, at 6 months, 1, 2, 5, 10 years and grade 3 in 0, 3.6, 20.3, 33.3, 11.1 % at the same time points. Slight differences were found between medial and lateral CMI in size and signal intensity. CONCLUSIONS: Higher rates of scaffolds with reduced size and with an MRI signal intensity more similar to normal meniscus were reported at longer follow-up compared with initial evaluations. Correlation between MRI findings and gross CMI appearance has not been reported. LEVEL OF EVIDENCE: IV.

MRI evaluation of a collagen meniscus implant: a systematic review / Zaffagnini, Stefano; Grassi, Alberto; Marcheggiani Muccioli, Giulio Maria; Bonanzinga, Tommaso; Nitri, Marco; Raggi, Federico; Ravazzolo, Giovanni; Marcacci, Maurilio. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - 23:11(2015), pp. 3228-3237. [10.1007/s00167-014-3155-6]

MRI evaluation of a collagen meniscus implant: a systematic review

ZAFFAGNINI, STEFANO;GRASSI, ALBERTO;MARCHEGGIANI MUCCIOLI, GIULIO MARIA;BONANZINGA, TOMMASO;NITRI, MARCO;RAGGI, FEDERICO;MARCACCI, MAURILIO
2015

Abstract

PURPOSE: Good clinical results have been demonstrated in numerous clinical studies using the collagen meniscus implant (CMI); however, the MRI behaviour of the scaffold, evaluated with Genovese score, is limited to a few cases series. The purpose was to evaluate, using the Genovese score, the MRI behaviour of the CMI at different follow-up periods and investigate possible differences in the behaviour of lateral and medial CMI. METHODS: A comprehensive search was performed on PubMed, Medline, CINAHL, Cochrane, Embase and Google Scholar databases using various combinations of the following keywords: "collagen meniscus implant" or "collagen meniscal implant". All the studies evaluating medial or lateral CMI using Genovese score for MRI were included in the systematic review. RESULTS: Six studies have been included in the systematic review, with no RCT's. The pooled number of patients involved in CMI surgery was 194 (83 % medial and 17 % lateral), with a mean age at surgery of 37.7 years. Concomitant procedures raged from 11 to 52 %. CMI morphology was grade 1 in 0, 2.7, 5.9, 0, 16.7 %, respectively, at 6 months, 1, 2, 5, 10 years. It was grade 2 in 12.5, 60.9, 60.3, 74.4, 75 %, respectively, at 6 months, 1, 2, 5, 10 years and grade 3 in 87.5, 36.4, 33.8, 25.6, 8.3 % at the same time points. CMI signal intensity was grade 1 in 80, 18.2, 25, 11.1, 22.2 %, respectively, at 6 months, 1, 2, 5, 10 years. It was grade 2 in 20, 78.2, 54.7, 55.6, 66.7 %, respectively, at 6 months, 1, 2, 5, 10 years and grade 3 in 0, 3.6, 20.3, 33.3, 11.1 % at the same time points. Slight differences were found between medial and lateral CMI in size and signal intensity. CONCLUSIONS: Higher rates of scaffolds with reduced size and with an MRI signal intensity more similar to normal meniscus were reported at longer follow-up compared with initial evaluations. Correlation between MRI findings and gross CMI appearance has not been reported. LEVEL OF EVIDENCE: IV.
2015
MRI evaluation of a collagen meniscus implant: a systematic review / Zaffagnini, Stefano; Grassi, Alberto; Marcheggiani Muccioli, Giulio Maria; Bonanzinga, Tommaso; Nitri, Marco; Raggi, Federico; Ravazzolo, Giovanni; Marcacci, Maurilio. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - 23:11(2015), pp. 3228-3237. [10.1007/s00167-014-3155-6]
Zaffagnini, Stefano; Grassi, Alberto; Marcheggiani Muccioli, Giulio Maria; Bonanzinga, Tommaso; Nitri, Marco; Raggi, Federico; Ravazzolo, Giovanni; Marcacci, Maurilio
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/520752
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 32
social impact