In vitro mechanical testing of spinal specimens is extremely important to better understand the biomechanics of the healthy and diseased spine, fracture, and to test/optimize surgical treatment. While spinal testing has extensively been carried out in the past four decades, testing methods are quite diverse. This paper aims to provide a critical overview of the in vitro methods for mechanical testing the human spine at different scales. Specimens of different type are used, according to the aim of the study: spine segments (two or more adjacent vertebrae) are used both to investigate the spine kinematics, and the mechanical properties of the spine components (vertebrae, ligaments, discs); single vertebrae (whole vertebra, isolated vertebral body, or vertebral body without endplates) are used to investigate the structural properties of the vertebra itself; core specimens are extracted to test the mechanical properties of the trabecular bone at the tissue-level; mechanical properties of spine soft tissue (discs, ligaments, spinal cord) are measured on isolated elements, or on tissue specimens. Identification of consistent reference frames is still a debated issue. Testing conditions feature different pre-conditioning and loading rates, depending on the simulated action. Tissue specimen preservation is a very critical issue, affecting test results. Animal models are often used as a surrogate. However, because of different structure and anatomy, extreme caution is required when extrapolating to the human spine. In vitro loading conditions should be based on reliable in vivo data. Because of the high complexity of the spine, such information (either through instrumented implants or through numerical modeling) is currently unsatisfactory. Because of the increasing ability of computational models in predicting biomechanical properties of musculoskeletal structures, a synergy is possible (and desirable) between in vitro experiments and numerical modeling. Future perspectives in spine testing include integration of mechanical and structural properties at different dimensional scales (from the whole-body-level down to the tissue-level) so that organ-level models (which are used to predict the most relevant phenomena such as fracture) include information from all dimensional scales.

Experimental methods for the biomechanical inestigation of the human spine: A reiew / Brandolini, N.; Cristofolini, L.; Viceconti, M.. - In: JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY. - ISSN 0219-5194. - STAMPA. - 14:1(2014), pp. 1430002-1-1430002-33. [10.1142/S0219519414300026]

Experimental methods for the biomechanical inestigation of the human spine: A reiew

CRISTOFOLINI, LUCA;VICECONTI, MARCO
2014

Abstract

In vitro mechanical testing of spinal specimens is extremely important to better understand the biomechanics of the healthy and diseased spine, fracture, and to test/optimize surgical treatment. While spinal testing has extensively been carried out in the past four decades, testing methods are quite diverse. This paper aims to provide a critical overview of the in vitro methods for mechanical testing the human spine at different scales. Specimens of different type are used, according to the aim of the study: spine segments (two or more adjacent vertebrae) are used both to investigate the spine kinematics, and the mechanical properties of the spine components (vertebrae, ligaments, discs); single vertebrae (whole vertebra, isolated vertebral body, or vertebral body without endplates) are used to investigate the structural properties of the vertebra itself; core specimens are extracted to test the mechanical properties of the trabecular bone at the tissue-level; mechanical properties of spine soft tissue (discs, ligaments, spinal cord) are measured on isolated elements, or on tissue specimens. Identification of consistent reference frames is still a debated issue. Testing conditions feature different pre-conditioning and loading rates, depending on the simulated action. Tissue specimen preservation is a very critical issue, affecting test results. Animal models are often used as a surrogate. However, because of different structure and anatomy, extreme caution is required when extrapolating to the human spine. In vitro loading conditions should be based on reliable in vivo data. Because of the high complexity of the spine, such information (either through instrumented implants or through numerical modeling) is currently unsatisfactory. Because of the increasing ability of computational models in predicting biomechanical properties of musculoskeletal structures, a synergy is possible (and desirable) between in vitro experiments and numerical modeling. Future perspectives in spine testing include integration of mechanical and structural properties at different dimensional scales (from the whole-body-level down to the tissue-level) so that organ-level models (which are used to predict the most relevant phenomena such as fracture) include information from all dimensional scales.
2014
Experimental methods for the biomechanical inestigation of the human spine: A reiew / Brandolini, N.; Cristofolini, L.; Viceconti, M.. - In: JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY. - ISSN 0219-5194. - STAMPA. - 14:1(2014), pp. 1430002-1-1430002-33. [10.1142/S0219519414300026]
Brandolini, N.; Cristofolini, L.; Viceconti, M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/519193
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 14
social impact