The IC presented integrates the front-end for EEG and Electrical Impedance Tomography (EIT) acquisition on the electrode, together with electrode-skin contact impedance monitoring and EIT current generation, so as to improve signal quality and integration of the two techniques for brain imaging applications. The electrode size is less than 2 cm(2) and only 4 wires connect the electrode to the back-end. The readout circuit is based on a Differential Difference Amplifier and performs single-ended amplification and frequency division multiplexing of the three signals that are sent to the back-end on a single wire which also provides power supply. Since the system's CMRR is a function of each electrode's gain accuracy, an analysis is performed on how this is influenced by mismatches in passive and active components. The circuit is fabricated in 0.35 μm CMOS process and occupies 4 mm(2), the readout circuit consumes 360 μW, the input referred noise for bipolar EEG signal acquisition is 0.56 μVRMS between 0.5 and 100 Hz and almost halves if only EEG signal is acquired.

Guermandi, M., Cardu, R., Franchi Scarselli, E., Guerrieri, R. (2015). Active Electrode IC for EEG and Electrical Impedance Tomography with Continuous monitoring of contact impedance. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 9(1), 21-33 [10.1109/TBCAS.2014.2311836].

Active Electrode IC for EEG and Electrical Impedance Tomography with Continuous monitoring of contact impedance

GUERMANDI, MARCO;CARDU, ROBERTO;FRANCHI SCARSELLI, ELEONORA;GUERRIERI, ROBERTO
2015

Abstract

The IC presented integrates the front-end for EEG and Electrical Impedance Tomography (EIT) acquisition on the electrode, together with electrode-skin contact impedance monitoring and EIT current generation, so as to improve signal quality and integration of the two techniques for brain imaging applications. The electrode size is less than 2 cm(2) and only 4 wires connect the electrode to the back-end. The readout circuit is based on a Differential Difference Amplifier and performs single-ended amplification and frequency division multiplexing of the three signals that are sent to the back-end on a single wire which also provides power supply. Since the system's CMRR is a function of each electrode's gain accuracy, an analysis is performed on how this is influenced by mismatches in passive and active components. The circuit is fabricated in 0.35 μm CMOS process and occupies 4 mm(2), the readout circuit consumes 360 μW, the input referred noise for bipolar EEG signal acquisition is 0.56 μVRMS between 0.5 and 100 Hz and almost halves if only EEG signal is acquired.
2015
Guermandi, M., Cardu, R., Franchi Scarselli, E., Guerrieri, R. (2015). Active Electrode IC for EEG and Electrical Impedance Tomography with Continuous monitoring of contact impedance. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 9(1), 21-33 [10.1109/TBCAS.2014.2311836].
Guermandi, Marco; Cardu, Roberto; Franchi Scarselli, Eleonora; Guerrieri, Roberto
File in questo prodotto:
File Dimensione Formato  
PP - Active_Electrode_IC_for_EEG_and_Electrical.pdf

Open Access dal 20/05/2016

Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 2.62 MB
Formato Adobe PDF
2.62 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/517819
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 66
social impact