In grid connected power converters both from renewable or traditional energy sources a line frequency transformer is usually employed in order to suppress the DC component. Recently, solutions based on a high frequency transformer or without transformer, usually referred as transformerless, are being investigated in order to reduce size, weight and costs. As a consequence, unless a suitable remedy is adopted, a DC component, that might overcome limits forced by international standards, may appear. This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in case of a full-bridge, single phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the Hall effect sensor mostly used as current transducer. Experimental results, performed for different current values and for different current control architectures, show the effectiveness of the proposed solution.

Buticchi, G., Franceschini, G., Lorenzani, E., Tassoni, C., Bellini, A. (2009). A novel current sensing DC offset compensation strategy in transformerless grid connected power converters [10.1109/ECCE.2009.5316339].

A novel current sensing DC offset compensation strategy in transformerless grid connected power converters

BELLINI, ALBERTO
2009

Abstract

In grid connected power converters both from renewable or traditional energy sources a line frequency transformer is usually employed in order to suppress the DC component. Recently, solutions based on a high frequency transformer or without transformer, usually referred as transformerless, are being investigated in order to reduce size, weight and costs. As a consequence, unless a suitable remedy is adopted, a DC component, that might overcome limits forced by international standards, may appear. This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in case of a full-bridge, single phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the Hall effect sensor mostly used as current transducer. Experimental results, performed for different current values and for different current control architectures, show the effectiveness of the proposed solution.
2009
Proceedings of IEEE Energy Conversion Congress and Exposition (ECCE), 2009.
3889
3894
Buticchi, G., Franceschini, G., Lorenzani, E., Tassoni, C., Bellini, A. (2009). A novel current sensing DC offset compensation strategy in transformerless grid connected power converters [10.1109/ECCE.2009.5316339].
Buticchi, G.; Franceschini, G.; Lorenzani, E.; Tassoni, C.; Bellini, A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/517022
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact