Voltage transients are one of the main causes of power quality degradation. There is a search for investigation techniques capable of characterizing and classifying them depending on their origin. A distributed measurement system for Power Quality (PQ) monitoring can be used in parallel with a Lightning Location System (LLS) to assess whether a lightning event is responsible for a voltage transient. This involves the accurate estimate of the transient’s starting instant. In this paper, a system for the measurement of the starting instant of voltage transients is described. It is hosted in each remote unit of a distributed system, built in our Laboratory, for PQ monitoring. The results of the characterization tests are also reported and discussed. They lead to conclude that our system for PQ monitoring can be used in parallel with LLS to assess whether an impulsive voltage transient was induced by lightning.

Implementation and Characterization of a System for the Evaluation of the Starting Instant of Lightning-Induced Transients / L. Peretto; P. Rinaldi; R. Sasdelli; R. Tinarelli; A. Fioravanti. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 56:(2007), pp. 1955-1960. [10.1109/IMTC.2004.1351326]

Implementation and Characterization of a System for the Evaluation of the Starting Instant of Lightning-Induced Transients

PERETTO, LORENZO;RINALDI, PAOLA;SASDELLI, RENATO;TINARELLI, ROBERTO;
2007

Abstract

Voltage transients are one of the main causes of power quality degradation. There is a search for investigation techniques capable of characterizing and classifying them depending on their origin. A distributed measurement system for Power Quality (PQ) monitoring can be used in parallel with a Lightning Location System (LLS) to assess whether a lightning event is responsible for a voltage transient. This involves the accurate estimate of the transient’s starting instant. In this paper, a system for the measurement of the starting instant of voltage transients is described. It is hosted in each remote unit of a distributed system, built in our Laboratory, for PQ monitoring. The results of the characterization tests are also reported and discussed. They lead to conclude that our system for PQ monitoring can be used in parallel with LLS to assess whether an impulsive voltage transient was induced by lightning.
2007
Implementation and Characterization of a System for the Evaluation of the Starting Instant of Lightning-Induced Transients / L. Peretto; P. Rinaldi; R. Sasdelli; R. Tinarelli; A. Fioravanti. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 56:(2007), pp. 1955-1960. [10.1109/IMTC.2004.1351326]
L. Peretto; P. Rinaldi; R. Sasdelli; R. Tinarelli; A. Fioravanti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/50283
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 3
social impact