A comparison between air and heliox (80% helium-20% oxygen) ventilation was performed using a mathematical, non-linear dynamic, morphometric model of the respiratory system. Different obstructive conditions, all causing expiratory flow limitation (EFL), were simulated during mechanical ventilation to evaluate and interpret the effects of heliox on tidal EFL and dynamic hyperinflation. Relative to air ventilation, intrinsic positive end-expiratory pressure did not change with heliox if the obstruction was limited to the peripheral airways, i.e. beyond the seventh generation. When central airways were also involved, heliox reduced dynamic hyperinflation (DH) if the flow-limiting segment remained in the fourth to seventh airway generation during the whole expiration, but produced only minor effects if, depending on the contribution of peripheral to total apparent airway resistance, the flow-limiting segment moved eventually to the peripheral airways. In no case did heliox abolish EFL occurring with air ventilation, indicating that any increase in driving pressure would be without effect on DH. Hence, to the extent that chronic obstructive pulmonary disease (COPD) affects primarily the peripheral airways, and causes EFL through the same mechanisms operating in the model, heliox administration should not be expected to appreciably reduce DH in the majority of COPD patients who are flow-limited at rest.

Helium-oxygen ventilation in the presence of expiratory flow-limitation: A model study

BRIGHENTI, CHIARA;GNUDI, GIANNI;
2007

Abstract

A comparison between air and heliox (80% helium-20% oxygen) ventilation was performed using a mathematical, non-linear dynamic, morphometric model of the respiratory system. Different obstructive conditions, all causing expiratory flow limitation (EFL), were simulated during mechanical ventilation to evaluate and interpret the effects of heliox on tidal EFL and dynamic hyperinflation. Relative to air ventilation, intrinsic positive end-expiratory pressure did not change with heliox if the obstruction was limited to the peripheral airways, i.e. beyond the seventh generation. When central airways were also involved, heliox reduced dynamic hyperinflation (DH) if the flow-limiting segment remained in the fourth to seventh airway generation during the whole expiration, but produced only minor effects if, depending on the contribution of peripheral to total apparent airway resistance, the flow-limiting segment moved eventually to the peripheral airways. In no case did heliox abolish EFL occurring with air ventilation, indicating that any increase in driving pressure would be without effect on DH. Hence, to the extent that chronic obstructive pulmonary disease (COPD) affects primarily the peripheral airways, and causes EFL through the same mechanisms operating in the model, heliox administration should not be expected to appreciably reduce DH in the majority of COPD patients who are flow-limited at rest.
2007
C. Brighenti; P. Barbini; G. Gnudi; G. Cevenini; M. Pecchiari; E. D'Angelo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/47175
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact