The recent development of new gamma imagers based on scintillation array with high spatial resolution, has strongly improved the possibility of detecting sub-centimeter cancer in Scintimammography. However, Compton scattering contamination remains the main drawback since it limits the sensitivity of tumor detection. Principal component image analysis (PCA), recently introduced in scintimammographic imaging, is a data reduction technique able to represent the radiation emitted from chest, breast healthy and damaged tissues as separated images. From these images a Scintimammography can be obtained where the Compton contamination is "removed". In the present paper we compared the PCA reconstructed images with the conventional scintimammographic images resulting from the photopeak (Ph) energy window. Data coming from a clinical trial were used. For both kinds of images the tumor presence was quantified by evaluating the t-student statistics for independent sample as a measure of the signal-to-noise ratio (SNR). Since the absence of Compton scattering, the PCA reconstructed images shows a better noise suppression and allows a more reliable diagnostics in comparison with the images obtained by the photopeak energy window, reducing the trend in producing false positive.

Bonifazzi C, Cinti MN, De Vincentis G, Finos L, Muzzioli V, Betti M, et al. (2006). Principal component analysis of scintimammographic images. PHYSICA MEDICA, 21, 91-93 [10.1016/S1120-1797(06)80034-7].

Principal component analysis of scintimammographic images

LANCONELLI, NICO;
2006

Abstract

The recent development of new gamma imagers based on scintillation array with high spatial resolution, has strongly improved the possibility of detecting sub-centimeter cancer in Scintimammography. However, Compton scattering contamination remains the main drawback since it limits the sensitivity of tumor detection. Principal component image analysis (PCA), recently introduced in scintimammographic imaging, is a data reduction technique able to represent the radiation emitted from chest, breast healthy and damaged tissues as separated images. From these images a Scintimammography can be obtained where the Compton contamination is "removed". In the present paper we compared the PCA reconstructed images with the conventional scintimammographic images resulting from the photopeak (Ph) energy window. Data coming from a clinical trial were used. For both kinds of images the tumor presence was quantified by evaluating the t-student statistics for independent sample as a measure of the signal-to-noise ratio (SNR). Since the absence of Compton scattering, the PCA reconstructed images shows a better noise suppression and allows a more reliable diagnostics in comparison with the images obtained by the photopeak energy window, reducing the trend in producing false positive.
2006
Bonifazzi C, Cinti MN, De Vincentis G, Finos L, Muzzioli V, Betti M, et al. (2006). Principal component analysis of scintimammographic images. PHYSICA MEDICA, 21, 91-93 [10.1016/S1120-1797(06)80034-7].
Bonifazzi C; Cinti MN; De Vincentis G; Finos L; Muzzioli V; Betti M; Lanconelli N; Tartari A; Pani R
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/45629
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact