AIM: Implant rehabilitation of the atrophic right posterior mandible in a 48-year-old woman using dehydrated homologous bone block, shaped with a computer aided design-computer aided manufacturing (CAD-CAM) system, to avoid harvesting of autologous bone block and to assure a perfect fitting of the block above the alveolar crest. RESULTS: After 7 months, 6.09, 7.36, and 8.08 mm (mean, 7.18 mm) of total horizontal bone gain was observed at sites 6, 12, and 18 mm posterior to the right mental foramen, respectively. CONCLUSIONS: The use of a bone block with CAD-CAM system for alveolar ridge augmentation is a valuable alternative to autograft because it reduces time, cost, and complications for the patients. Data from a computerized tomographic scan can be used to shape a precise 3-dimensional homologous bone block using a CAD-CAM system.

Posterior atrophic mandible rehabilitation with onlay allograft created with CAD-CAM procedure: a case report / Jacotti M;Barausse C;Felice P. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - STAMPA. - 23:(2014), pp. 22-28. [10.1097/ID.0000000000000023]

Posterior atrophic mandible rehabilitation with onlay allograft created with CAD-CAM procedure: a case report.

BARAUSSE, CARLO;FELICE, PIETRO
2014

Abstract

AIM: Implant rehabilitation of the atrophic right posterior mandible in a 48-year-old woman using dehydrated homologous bone block, shaped with a computer aided design-computer aided manufacturing (CAD-CAM) system, to avoid harvesting of autologous bone block and to assure a perfect fitting of the block above the alveolar crest. RESULTS: After 7 months, 6.09, 7.36, and 8.08 mm (mean, 7.18 mm) of total horizontal bone gain was observed at sites 6, 12, and 18 mm posterior to the right mental foramen, respectively. CONCLUSIONS: The use of a bone block with CAD-CAM system for alveolar ridge augmentation is a valuable alternative to autograft because it reduces time, cost, and complications for the patients. Data from a computerized tomographic scan can be used to shape a precise 3-dimensional homologous bone block using a CAD-CAM system.
2014
Posterior atrophic mandible rehabilitation with onlay allograft created with CAD-CAM procedure: a case report / Jacotti M;Barausse C;Felice P. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - STAMPA. - 23:(2014), pp. 22-28. [10.1097/ID.0000000000000023]
Jacotti M;Barausse C;Felice P
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/397990
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 39
social impact