BACKGROUND: Sensor-augmented continuous subcutaneous insulin infusion (CSII) therapy is superior to CSII therapy alone, but little is known on the effectiveness of sensor-augmented multiple daily injections (MDI) therapy. METHODS: We compared during everyday life mean glucose control and several variability indexes recorded for 3 days by a real-time glucose sensor (Medtronic, Northridge, CA) in two groups of children treated with either CSII or MDI. Fifty-five consecutive subjects were examined: 17 receiving CSII and 38 receiving MDI basal-bolus therapy (age range, 7-22 years). All subjects wore the sensor for 4 days, and 3 days were used for statistical analysis. Mean glucose and SD, coefficient of variation (CV), mean amplitude of glucose excursion (MAGE), mean of daily differences (MODD), continuous overall net glycemic action (CONGA) at 2 and 4 h, blood glucose (BG) rate, area under the curve (AUC) above 180 mg/dL and below 70 mg/dL, Low BG Index (LBGI), and High BG Index (HBGI) were calculated. RESULTS: Patients receiving CSII administered more daily boluses than patients receiving MDI (5.2±1.5 vs. 3.2±0.3, respectively; P=0.001). Mean glucose was lower in the CSII group. AUC above 180 mg/dL and HBGI were higher in the MDI group. CV, CONGA at 2 h, CONGA at 2 h during the day, and HBGI were worse in the MDI group, whereas MODD, LBGI, BG rate, and MAGE were similar. A positive correlation (r=0.95; P<0.05) was found between the paired sensor-meter values. For the glucose values <70 mg/dL, sensitivity was 40%, and specificity was 99%. CONCLUSIONS: In our pediatric patients during everyday life sensor-augmented CSII therapy seemed more effective than sensor-augmented MDI therapy, in terms both of glucose mean values and of intraday variability. Mild hypoglycemic episodes and indexes of low BG values were similar in the two groups, although the latter results may be inaccurate because of low sensor sensitivity at low glucose value.

Comparison Between Sensor-Augmented Insulin Therapy with Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections in Everyday Life: 3-Day Analysis of Glucose Patterns and Sensor Accuracy in Children / Stefano Zucchini;Mirella Scipione;Claudia Balsamo;Giulio Maltoni;Alessandra Rollo;Emanuela Molinari;Lorenza Mangoni;Alessandro Cicognani. - In: DIABETES TECHNOLOGY & THERAPEUTICS. - ISSN 1520-9156. - STAMPA. - 13:(2011), pp. 1187-1193. [10.1089/dia.2011.0080]

Comparison Between Sensor-Augmented Insulin Therapy with Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections in Everyday Life: 3-Day Analysis of Glucose Patterns and Sensor Accuracy in Children

ZUCCHINI, STEFANO;MALTONI, GIULIO;
2011

Abstract

BACKGROUND: Sensor-augmented continuous subcutaneous insulin infusion (CSII) therapy is superior to CSII therapy alone, but little is known on the effectiveness of sensor-augmented multiple daily injections (MDI) therapy. METHODS: We compared during everyday life mean glucose control and several variability indexes recorded for 3 days by a real-time glucose sensor (Medtronic, Northridge, CA) in two groups of children treated with either CSII or MDI. Fifty-five consecutive subjects were examined: 17 receiving CSII and 38 receiving MDI basal-bolus therapy (age range, 7-22 years). All subjects wore the sensor for 4 days, and 3 days were used for statistical analysis. Mean glucose and SD, coefficient of variation (CV), mean amplitude of glucose excursion (MAGE), mean of daily differences (MODD), continuous overall net glycemic action (CONGA) at 2 and 4 h, blood glucose (BG) rate, area under the curve (AUC) above 180 mg/dL and below 70 mg/dL, Low BG Index (LBGI), and High BG Index (HBGI) were calculated. RESULTS: Patients receiving CSII administered more daily boluses than patients receiving MDI (5.2±1.5 vs. 3.2±0.3, respectively; P=0.001). Mean glucose was lower in the CSII group. AUC above 180 mg/dL and HBGI were higher in the MDI group. CV, CONGA at 2 h, CONGA at 2 h during the day, and HBGI were worse in the MDI group, whereas MODD, LBGI, BG rate, and MAGE were similar. A positive correlation (r=0.95; P<0.05) was found between the paired sensor-meter values. For the glucose values <70 mg/dL, sensitivity was 40%, and specificity was 99%. CONCLUSIONS: In our pediatric patients during everyday life sensor-augmented CSII therapy seemed more effective than sensor-augmented MDI therapy, in terms both of glucose mean values and of intraday variability. Mild hypoglycemic episodes and indexes of low BG values were similar in the two groups, although the latter results may be inaccurate because of low sensor sensitivity at low glucose value.
2011
Comparison Between Sensor-Augmented Insulin Therapy with Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections in Everyday Life: 3-Day Analysis of Glucose Patterns and Sensor Accuracy in Children / Stefano Zucchini;Mirella Scipione;Claudia Balsamo;Giulio Maltoni;Alessandra Rollo;Emanuela Molinari;Lorenza Mangoni;Alessandro Cicognani. - In: DIABETES TECHNOLOGY & THERAPEUTICS. - ISSN 1520-9156. - STAMPA. - 13:(2011), pp. 1187-1193. [10.1089/dia.2011.0080]
Stefano Zucchini;Mirella Scipione;Claudia Balsamo;Giulio Maltoni;Alessandra Rollo;Emanuela Molinari;Lorenza Mangoni;Alessandro Cicognani
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/396750
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact