Abstract OBJECTIVE: Repair of partial anomalous pulmonary venous connection to superior vena cava using an internal patch has been described as a potential cause of obstruction at the systemic or pulmonary vein level and of sinus node dysfunction. Our experience with this operation was reviewed. METHODS: From 1991 to 2011, 59 patients with a diagnosis of partial anomalous pulmonary venous connection to superior vena cava underwent surgical repair with intracardiac patch rerouting alone (45 patients) or with associated superior vena cava patch enlargement (14 patients). Follow-up evaluation was performed, including electrocardiogram, echocardiogram, electrocardiogram Holter monitor recording, and exercise stress test. RESULTS: There were no early or late deaths and no reoperations at a mean follow-up of 46 ± 45 months. All patients were asymptomatic in New York Heart Association class I. Echocardiographic evaluation excluded any obstruction at the pulmonary or systemic vein level. At follow-up, 55 patients (93%) presented sinus rhythm and were free from antiarrhythmic medications, 2 patients (3%) presented atrial fibrillation, 1 patient (2%) presented atrial fibrillation and asymptomatic sinus node dysfunction, and 1 patient (2%) presented ectopic atrial rhythm. Electrocardiogram Holter recording demonstrated sinus node dysfunction in 6 of 34 patients (18%). Exercise stress test showed chronotropic incompetence in 8 of 27 patients (30%): All except 1 patient presented sinus rhythm at basal electrocardiogram, and only 4 patients had some evidence of sinus node dysfunction on electrocardiogram Holter recording. CONCLUSIONS: Intracardiac repair of partial anomalous pulmonary venous connection can be performed with good results at medium-term follow-up. The rate of sinus node dysfunction or other arrhythmias and obstruction at pulmonary or systemic vein level is comparable to other techniques. Exercise stress test evaluation is the best way to detect asymptomatic sinus node dysfunction.

Sinus node dysfunction after partial anomalous pulmonary venous connection repair / Pace Napoleone C;Mariucci E;Angeli E;Oppido G;Gargiulo GD. - In: JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY. - ISSN 0022-5223. - STAMPA. - 147:5(2014), pp. 1594-1598. [10.1016/j.jtcvs.2013.07.058]

Sinus node dysfunction after partial anomalous pulmonary venous connection repair.

GARGIULO, GAETANO DOMENICO
2014

Abstract

Abstract OBJECTIVE: Repair of partial anomalous pulmonary venous connection to superior vena cava using an internal patch has been described as a potential cause of obstruction at the systemic or pulmonary vein level and of sinus node dysfunction. Our experience with this operation was reviewed. METHODS: From 1991 to 2011, 59 patients with a diagnosis of partial anomalous pulmonary venous connection to superior vena cava underwent surgical repair with intracardiac patch rerouting alone (45 patients) or with associated superior vena cava patch enlargement (14 patients). Follow-up evaluation was performed, including electrocardiogram, echocardiogram, electrocardiogram Holter monitor recording, and exercise stress test. RESULTS: There were no early or late deaths and no reoperations at a mean follow-up of 46 ± 45 months. All patients were asymptomatic in New York Heart Association class I. Echocardiographic evaluation excluded any obstruction at the pulmonary or systemic vein level. At follow-up, 55 patients (93%) presented sinus rhythm and were free from antiarrhythmic medications, 2 patients (3%) presented atrial fibrillation, 1 patient (2%) presented atrial fibrillation and asymptomatic sinus node dysfunction, and 1 patient (2%) presented ectopic atrial rhythm. Electrocardiogram Holter recording demonstrated sinus node dysfunction in 6 of 34 patients (18%). Exercise stress test showed chronotropic incompetence in 8 of 27 patients (30%): All except 1 patient presented sinus rhythm at basal electrocardiogram, and only 4 patients had some evidence of sinus node dysfunction on electrocardiogram Holter recording. CONCLUSIONS: Intracardiac repair of partial anomalous pulmonary venous connection can be performed with good results at medium-term follow-up. The rate of sinus node dysfunction or other arrhythmias and obstruction at pulmonary or systemic vein level is comparable to other techniques. Exercise stress test evaluation is the best way to detect asymptomatic sinus node dysfunction.
2014
Sinus node dysfunction after partial anomalous pulmonary venous connection repair / Pace Napoleone C;Mariucci E;Angeli E;Oppido G;Gargiulo GD. - In: JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY. - ISSN 0022-5223. - STAMPA. - 147:5(2014), pp. 1594-1598. [10.1016/j.jtcvs.2013.07.058]
Pace Napoleone C;Mariucci E;Angeli E;Oppido G;Gargiulo GD
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/396463
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact