here has been an increased interest in the quantification of the knee laxity secondary to anterior cruciate ligament (ACL) injury. In clinical practice, the diagnosis is performed by clinical examination and magnetic resonance imaging analysis and confirmed arthroscopically. The pivot shift phenomenon has been identified as one of the essential signs of functional ACL insufficiency. A reliable system to adequately assess patients with ACL injury, quantifying the pivot shift test outcome, is needed. Several studies have been conducted in this regard but the proposed methods remain confined to a research area. The goal of this article is to summarize the actual knowledge and current concepts.

Innovative technology for knee laxity evaluation: clinical applicability and reliability of inertial sensors for quantitative analysis of the pivot-shift test / Zaffagnini S;Lopomo N;Signorelli C;Marcheggiani Muccioli GM;Bonanzinga T;Grassi A;Visani A;Marcacci M. - In: CLINICS IN SPORTS MEDICINE. - ISSN 0278-5919. - STAMPA. - 32:1(2013), pp. 61-70. [10.1016/j.csm.2012.08.007]

Innovative technology for knee laxity evaluation: clinical applicability and reliability of inertial sensors for quantitative analysis of the pivot-shift test.

ZAFFAGNINI, STEFANO;MARCHEGGIANI MUCCIOLI, GIULIO MARIA;BONANZINGA, TOMMASO;MARCACCI, MAURILIO
2013

Abstract

here has been an increased interest in the quantification of the knee laxity secondary to anterior cruciate ligament (ACL) injury. In clinical practice, the diagnosis is performed by clinical examination and magnetic resonance imaging analysis and confirmed arthroscopically. The pivot shift phenomenon has been identified as one of the essential signs of functional ACL insufficiency. A reliable system to adequately assess patients with ACL injury, quantifying the pivot shift test outcome, is needed. Several studies have been conducted in this regard but the proposed methods remain confined to a research area. The goal of this article is to summarize the actual knowledge and current concepts.
2013
Innovative technology for knee laxity evaluation: clinical applicability and reliability of inertial sensors for quantitative analysis of the pivot-shift test / Zaffagnini S;Lopomo N;Signorelli C;Marcheggiani Muccioli GM;Bonanzinga T;Grassi A;Visani A;Marcacci M. - In: CLINICS IN SPORTS MEDICINE. - ISSN 0278-5919. - STAMPA. - 32:1(2013), pp. 61-70. [10.1016/j.csm.2012.08.007]
Zaffagnini S;Lopomo N;Signorelli C;Marcheggiani Muccioli GM;Bonanzinga T;Grassi A;Visani A;Marcacci M
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/394526
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 21
social impact