Abstract AIM: The aim of this paper was to compare hospital outcomes in patients undergoing elective surgery of the thoracic aorta using the right axillary artery (RAA) and the innominate artery (IA) as a cannulation site for cardiopulmonary bypass (CPB) arterial inflow. METHODS: Between September 2009 and October 2011, 71 patients underwent elective aortic procedures with RAA (N.=27) and IA (N.=44) cannulation. Selection of RAA vs. IA was not randomized, but rather based on surgical judgment of best indication in each patient. Pre-, intra-, and postoperative variables were compared according to cannulation site. RESULTS: Preoperative comorbidities, underlying aortic pathology, and surgical procedures were similar in RAA and IA patients. Hospital mortality was 11.1% and 6.8% in RAA and IA patients, respectively (P=0.243). Overall, 4 brain infarctions occurred, all left sided (RAA: 3.7% vs. IA: 6.8%; P=0.508). One brachial plexus injury, and 1 arterial dissection occurred in RAA group. No cannulation-related morbidity was observed in IA patients. Theoretical CPB flow could be reached in all patients, but resistances through the cannulation sites were more favourable in IA patients. CONCLUSION: RAA and IA were associated with similarly valid results. The choice between the two, based on the specific patient's characteristics, can improve outcomes after aortic surgery.

Axillary and innominate artery cannulation during surgery of the thoracic aorta: a comparative study / Di Eusanio M;Dimitri Petridis F;Folesani G;Berretta P;Zardin D;Di Bartolomeo R. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - STAMPA. - 55:(2014), pp. 841-847.

Axillary and innominate artery cannulation during surgery of the thoracic aorta: a comparative study.

DI EUSANIO, MARCO;FOLESANI, GIANLUCA;BERRETTA, PAOLO;DI BARTOLOMEO, ROBERTO
2014

Abstract

Abstract AIM: The aim of this paper was to compare hospital outcomes in patients undergoing elective surgery of the thoracic aorta using the right axillary artery (RAA) and the innominate artery (IA) as a cannulation site for cardiopulmonary bypass (CPB) arterial inflow. METHODS: Between September 2009 and October 2011, 71 patients underwent elective aortic procedures with RAA (N.=27) and IA (N.=44) cannulation. Selection of RAA vs. IA was not randomized, but rather based on surgical judgment of best indication in each patient. Pre-, intra-, and postoperative variables were compared according to cannulation site. RESULTS: Preoperative comorbidities, underlying aortic pathology, and surgical procedures were similar in RAA and IA patients. Hospital mortality was 11.1% and 6.8% in RAA and IA patients, respectively (P=0.243). Overall, 4 brain infarctions occurred, all left sided (RAA: 3.7% vs. IA: 6.8%; P=0.508). One brachial plexus injury, and 1 arterial dissection occurred in RAA group. No cannulation-related morbidity was observed in IA patients. Theoretical CPB flow could be reached in all patients, but resistances through the cannulation sites were more favourable in IA patients. CONCLUSION: RAA and IA were associated with similarly valid results. The choice between the two, based on the specific patient's characteristics, can improve outcomes after aortic surgery.
2014
Axillary and innominate artery cannulation during surgery of the thoracic aorta: a comparative study / Di Eusanio M;Dimitri Petridis F;Folesani G;Berretta P;Zardin D;Di Bartolomeo R. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - STAMPA. - 55:(2014), pp. 841-847.
Di Eusanio M;Dimitri Petridis F;Folesani G;Berretta P;Zardin D;Di Bartolomeo R
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/393874
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact