The diagnostic role of audio-impedancemetry in superior semicircular canal dehiscence (SSCD) disease is well known. in particular, since the first reports, the presence of evoked acoustic reflexes has represented a determining instrumental exhibit in differential diagnosis with other middle ear pathologies that are responsible for a mild-low frequencies air-bone gap (ABg). Even though high resolution computed tomogra-phy (hrCT) completed by parasagittal reformatted images still represents the diagnostic gold standard, several instrumental tests can support a suspect of labyrinthine capsule dehiscence when "suggestive" symptoms occur. objective and subjective audiometry often represents the start-ing point of the diagnostic course aimed at investigating the cause responsible for the so-called "intra-labyrinthine conductive hearing loss". The purpose of this study is to evaluate the role of tympanometry, in particular of the inter-aural asymmetry ratio in peak compliance as a function of different mild-low frequencies ABg on the affected side, in the diagnostic work-up in patients with unilateral SSCD. The working hypothesis is that an increase in admittance of the "inner-middle ear" conduction system due to a "third mobile window" could be detected by tympanometry. A retrospective review of the clinical records of 45 patients with unilateral dehiscence selected from a pool of 140 subjects diagnosed with SSCD at our institution from 2003 to 2011 was performed. Values of ABg amplitude on the dehiscent side and tympanometric measurements of both ears were collected for each patient in the study group (n = 45). An asymmetry between tympa-nometric peak compliance of the involved side and that of the contralateral side was investigated by calculating the inter-aural difference and the asymmetry ratio of compliance at the eardrum. A statistically significant correlation (p = 0. 015 by Fisher's test) between an asym-metry ratio ≥ 14% in favour of the pathologic ear and an ABg > 20 dB nhl on the same side was found. When "evocative" symptoms of SSCD associated with important ABg occur, the inter-aural difference in tympanometric peak compliance at the eardrum in favour of the "suspected" side could suggest an intra-labyrinthine origin for the asymmetry. Tympanometry would thus prove to be a useful instrument in clinical-instrumental diagnosis of SSCD in detection of cases associated with alterations of inner ear impedance.

Tympanometric findings in superior semicircular canal dehiscence syndrome / Castellucci A;Brandolini C;Piras G;Modugno GC. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 0392-100X. - STAMPA. - 33:2(2013), pp. 112-120.

Tympanometric findings in superior semicircular canal dehiscence syndrome.

CASTELLUCCI, ANDREA;BRANDOLINI, CRISTINA;PIRAS, GIANLUCA;MODUGNO, GIOVANNI CARLO
2013

Abstract

The diagnostic role of audio-impedancemetry in superior semicircular canal dehiscence (SSCD) disease is well known. in particular, since the first reports, the presence of evoked acoustic reflexes has represented a determining instrumental exhibit in differential diagnosis with other middle ear pathologies that are responsible for a mild-low frequencies air-bone gap (ABg). Even though high resolution computed tomogra-phy (hrCT) completed by parasagittal reformatted images still represents the diagnostic gold standard, several instrumental tests can support a suspect of labyrinthine capsule dehiscence when "suggestive" symptoms occur. objective and subjective audiometry often represents the start-ing point of the diagnostic course aimed at investigating the cause responsible for the so-called "intra-labyrinthine conductive hearing loss". The purpose of this study is to evaluate the role of tympanometry, in particular of the inter-aural asymmetry ratio in peak compliance as a function of different mild-low frequencies ABg on the affected side, in the diagnostic work-up in patients with unilateral SSCD. The working hypothesis is that an increase in admittance of the "inner-middle ear" conduction system due to a "third mobile window" could be detected by tympanometry. A retrospective review of the clinical records of 45 patients with unilateral dehiscence selected from a pool of 140 subjects diagnosed with SSCD at our institution from 2003 to 2011 was performed. Values of ABg amplitude on the dehiscent side and tympanometric measurements of both ears were collected for each patient in the study group (n = 45). An asymmetry between tympa-nometric peak compliance of the involved side and that of the contralateral side was investigated by calculating the inter-aural difference and the asymmetry ratio of compliance at the eardrum. A statistically significant correlation (p = 0. 015 by Fisher's test) between an asym-metry ratio ≥ 14% in favour of the pathologic ear and an ABg > 20 dB nhl on the same side was found. When "evocative" symptoms of SSCD associated with important ABg occur, the inter-aural difference in tympanometric peak compliance at the eardrum in favour of the "suspected" side could suggest an intra-labyrinthine origin for the asymmetry. Tympanometry would thus prove to be a useful instrument in clinical-instrumental diagnosis of SSCD in detection of cases associated with alterations of inner ear impedance.
2013
Tympanometric findings in superior semicircular canal dehiscence syndrome / Castellucci A;Brandolini C;Piras G;Modugno GC. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 0392-100X. - STAMPA. - 33:2(2013), pp. 112-120.
Castellucci A;Brandolini C;Piras G;Modugno GC
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/393795
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact