Abstract INTRODUCTION: Tibial plateau articular pathology caused by post-traumatic or degenerative lesions is a challenge for the orthopaedic surgeon and can lead to early osteoarthritis. The aim of the present study was to evaluate the results of treatment of these complex defects with implantation of an osteochondral scaffold, which is designed to target the cartilage surface and to reconstruct joint anatomy by addressing the entire osteochondral unit. MATERIALS AND METHODS: Eleven patients (5 female and 6 male) with a mean age of 37.3±11.0 years and osteochondral lesions of the tibial plateau (mean 5.1±2.7cm(2); range 3.0-12.5cm(2)) were treated with the implantation of an osteochondral biomimetic collagen-hydroxyapatite scaffold (Maioregen(®), Fin-Ceramica, Faenza, Italy). Comorbidities were addressed taking care to restore the correct limb alignment. Patients were evaluated pre-operatively and prospectively followed-up for 2 years using the International Knee Documentation Committee (IKDC) subjective and objective scores; activity level was documented using the Tegner score. RESULTS: Three patients experienced minor adverse events. No patients required further surgery for treatment failure during the study follow-up period, and 8 patients (72.7%) reported a marked improvement. The IKDC subjective score improved from 42.5±10.2 before treatment to 69.8±19.0 at 12 months (p<0.05), with stable results at 24 months. The IKDC objective score increased from 27.3% normal and nearly normal knees before treatment to 85.7% normal and nearly normal knees at 24 months of follow-up. The Tegner score increased from 2.3±2.1 before treatment to 4.8±2.4 at 12 months (p<0.05), and was stable at the final follow-up. CONCLUSION: The present study on the implantation of an osteochondral scaffold for the treatment of tibial plateau lesions showed a promising clinical outcome at short-term follow-up, which indicates that this procedure can be considered as a possible treatment option, even in these complex defects, when comorbidities are concomitantly addressed.

Kon E, Filardo G, Venieri G, Perdisa F, Marcacci M (2014). Tibial plateau lesions. Surface reconstruction with a biomimetic osteochondral scaffold: Results at 2 years of follow-up. INJURY, 45 Suppl 6, S121-S125 [10.1016/j.injury.2014.10.035].

Tibial plateau lesions. Surface reconstruction with a biomimetic osteochondral scaffold: Results at 2 years of follow-up.

KON, ELIZAVETA;FILARDO, GIUSEPPE;MARCACCI, MAURILIO
2014

Abstract

Abstract INTRODUCTION: Tibial plateau articular pathology caused by post-traumatic or degenerative lesions is a challenge for the orthopaedic surgeon and can lead to early osteoarthritis. The aim of the present study was to evaluate the results of treatment of these complex defects with implantation of an osteochondral scaffold, which is designed to target the cartilage surface and to reconstruct joint anatomy by addressing the entire osteochondral unit. MATERIALS AND METHODS: Eleven patients (5 female and 6 male) with a mean age of 37.3±11.0 years and osteochondral lesions of the tibial plateau (mean 5.1±2.7cm(2); range 3.0-12.5cm(2)) were treated with the implantation of an osteochondral biomimetic collagen-hydroxyapatite scaffold (Maioregen(®), Fin-Ceramica, Faenza, Italy). Comorbidities were addressed taking care to restore the correct limb alignment. Patients were evaluated pre-operatively and prospectively followed-up for 2 years using the International Knee Documentation Committee (IKDC) subjective and objective scores; activity level was documented using the Tegner score. RESULTS: Three patients experienced minor adverse events. No patients required further surgery for treatment failure during the study follow-up period, and 8 patients (72.7%) reported a marked improvement. The IKDC subjective score improved from 42.5±10.2 before treatment to 69.8±19.0 at 12 months (p<0.05), with stable results at 24 months. The IKDC objective score increased from 27.3% normal and nearly normal knees before treatment to 85.7% normal and nearly normal knees at 24 months of follow-up. The Tegner score increased from 2.3±2.1 before treatment to 4.8±2.4 at 12 months (p<0.05), and was stable at the final follow-up. CONCLUSION: The present study on the implantation of an osteochondral scaffold for the treatment of tibial plateau lesions showed a promising clinical outcome at short-term follow-up, which indicates that this procedure can be considered as a possible treatment option, even in these complex defects, when comorbidities are concomitantly addressed.
2014
Kon E, Filardo G, Venieri G, Perdisa F, Marcacci M (2014). Tibial plateau lesions. Surface reconstruction with a biomimetic osteochondral scaffold: Results at 2 years of follow-up. INJURY, 45 Suppl 6, S121-S125 [10.1016/j.injury.2014.10.035].
Kon E;Filardo G;Venieri G;Perdisa F;Marcacci M
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/393743
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 24
social impact