AIMS: To investigate the technical feasibility of utilizing the Active Breathing Coordinator for planning of postoperative three-dimensional conformal radiation therapy in patients with early stage breast cancer undergoing breast conservation therapy. METHODS: Patients with early stage breast cancer for whom adjuvant radiotherapy after breast-conserving surgery was planned were consecutively enrolled. Five sessions of simulation with the Active Breathing Coordinator were planned for each patient. Computed tomography for simulation was not acquired until a good level of compliance with the procedure was achieved by the patient. Patients who did not show a satisfactory level of compliance after the planned fifth session were defined as noncompliant. Two simulation computed tomography scans were acquired: the first without the Active Breathing Coordinator during free breathing, the second with the Active Breathing Coordinator. Forward intensity-modulated treatment plans were calculated. Mean lung dose (MLDipsilateral) and V30 (V30lung) for the ipsilateral lung and V30 for the heart (V30heart), were evaluated. RESULTS: Twenty consecutive patients were enrolled (6 with left-sided breast cancer and 14 with right-sided breast cancer). Eighteen of the patients completed the simulation computed tomography with the Active Breathing Coordinator after 1-5 sessions (median, 3). In 16 of the 18 patients, a reduction of V301ung was observed with the Active Breathing Coordinator. In 15 of the 18 patients, a reduction of MLDipsiateral was also observed. In 5 of the 6 patients with left-sided breast cancer, a reduction of V30heart was noted. CONCLUSIONS: Routine application of the Active Breathing Coordinator in clinical practice is feasible, even though it requires an increased workload. Dosimetric results are encouraging in terms of a better sparing of the ipsilateral lung and the heart.
Massaccesi, M., Caravatta, L., Cilla, S., Digesù, C., Deodato, F., Macchia, G., et al. (2010). Active Breathing Coordinator in adjuvant three-dimensional conformal radiotherapy of early stage breast cancer: a feasibility study. TUMORI, 96, 417-423.
Active Breathing Coordinator in adjuvant three-dimensional conformal radiotherapy of early stage breast cancer: a feasibility study
MORGANTI, ALESSIO GIUSEPPE
2010
Abstract
AIMS: To investigate the technical feasibility of utilizing the Active Breathing Coordinator for planning of postoperative three-dimensional conformal radiation therapy in patients with early stage breast cancer undergoing breast conservation therapy. METHODS: Patients with early stage breast cancer for whom adjuvant radiotherapy after breast-conserving surgery was planned were consecutively enrolled. Five sessions of simulation with the Active Breathing Coordinator were planned for each patient. Computed tomography for simulation was not acquired until a good level of compliance with the procedure was achieved by the patient. Patients who did not show a satisfactory level of compliance after the planned fifth session were defined as noncompliant. Two simulation computed tomography scans were acquired: the first without the Active Breathing Coordinator during free breathing, the second with the Active Breathing Coordinator. Forward intensity-modulated treatment plans were calculated. Mean lung dose (MLDipsilateral) and V30 (V30lung) for the ipsilateral lung and V30 for the heart (V30heart), were evaluated. RESULTS: Twenty consecutive patients were enrolled (6 with left-sided breast cancer and 14 with right-sided breast cancer). Eighteen of the patients completed the simulation computed tomography with the Active Breathing Coordinator after 1-5 sessions (median, 3). In 16 of the 18 patients, a reduction of V301ung was observed with the Active Breathing Coordinator. In 15 of the 18 patients, a reduction of MLDipsiateral was also observed. In 5 of the 6 patients with left-sided breast cancer, a reduction of V30heart was noted. CONCLUSIONS: Routine application of the Active Breathing Coordinator in clinical practice is feasible, even though it requires an increased workload. Dosimetric results are encouraging in terms of a better sparing of the ipsilateral lung and the heart.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.