We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In this work, we describe the structure of this application and present the tests performed to validate it against reference data and experiments. We used the spheres of a NEMA phantom to calculate S values and total doses. The comparison with reference data from OLINDA/EXM showed an agreement within 2% for a sphere size above 2.8 cm diameter. A custom heterogeneous phantom composed of several layers of Perspex and lung equivalent material was used to compare TLD measurements of gamma radiation from (131)I to Monte Carlo simulations. An agreement within 5% was found. RAYDOSE has been validated against reference data and experimental measurements and can be a useful multi-modality platform for treatment planning and research in MRT.

Marcatili S., Pettinato C., Daniels S., Lewis G., Edwards P., Fanti S., et al. (2013). Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy. PHYSICS IN MEDICINE AND BIOLOGY, 58, 2491-2508 [10.1088/0031-9155/58/8/2491].

Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

FANTI, STEFANO;
2013

Abstract

We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In this work, we describe the structure of this application and present the tests performed to validate it against reference data and experiments. We used the spheres of a NEMA phantom to calculate S values and total doses. The comparison with reference data from OLINDA/EXM showed an agreement within 2% for a sphere size above 2.8 cm diameter. A custom heterogeneous phantom composed of several layers of Perspex and lung equivalent material was used to compare TLD measurements of gamma radiation from (131)I to Monte Carlo simulations. An agreement within 5% was found. RAYDOSE has been validated against reference data and experimental measurements and can be a useful multi-modality platform for treatment planning and research in MRT.
2013
Marcatili S., Pettinato C., Daniels S., Lewis G., Edwards P., Fanti S., et al. (2013). Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy. PHYSICS IN MEDICINE AND BIOLOGY, 58, 2491-2508 [10.1088/0031-9155/58/8/2491].
Marcatili S.; Pettinato C.; Daniels S.; Lewis G.; Edwards P.; Fanti S.; Spezi E.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/386279
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 17
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 53