A sensitive and specific HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma has been developed and validated. Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid using a polymer-based amino high-performance liquid chromatography (HPLC) column and a water/acetonitrile mobile phase elution gradient, with d-[1-(13)C]glucosamine as the internal standard. Detection was performed by mass spectrometry, using an electrospray source and employing multiple reaction monitoring to separately monitor glucosamine and the internal standard. The limit of quantification of the method was 10ng/ml of glucosamine and the calibration curve showed a good linearity up to 1000ng/ml. The precision (R.S.D.) and the accuracy (bias) of the method at the limit of quantification were 13.8 and 4.0%, respectively, and the mean recovery of glucosamine at three concentration levels was 101.6+/-5.7%. The method was applied for the determination of glucosamine concentrations in human plasma samples collected from untreated healthy volunteers and, in a separate bioavailability study, to evaluate plasma glucosamine pharmacokinetics profiles after oral administration of crystalline glucosamine sulfate.

Roda A., Sabatini L., Barbieri A., Guardigli M., Locatelli M., Violante F.S., et al. (2006). Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma. JOURNAL OF CHROMATOGRAPHY. B, 844, 119-126 [10.1016/j.jchromb.2006.07.013].

Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma

RODA, ALDO;SABATINI, LAURA;BARBIERI, ANNA;GUARDIGLI, MASSIMO;LOCATELLI, MARCELLO;VIOLANTE, FRANCESCO SAVERIO;
2006

Abstract

A sensitive and specific HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma has been developed and validated. Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid using a polymer-based amino high-performance liquid chromatography (HPLC) column and a water/acetonitrile mobile phase elution gradient, with d-[1-(13)C]glucosamine as the internal standard. Detection was performed by mass spectrometry, using an electrospray source and employing multiple reaction monitoring to separately monitor glucosamine and the internal standard. The limit of quantification of the method was 10ng/ml of glucosamine and the calibration curve showed a good linearity up to 1000ng/ml. The precision (R.S.D.) and the accuracy (bias) of the method at the limit of quantification were 13.8 and 4.0%, respectively, and the mean recovery of glucosamine at three concentration levels was 101.6+/-5.7%. The method was applied for the determination of glucosamine concentrations in human plasma samples collected from untreated healthy volunteers and, in a separate bioavailability study, to evaluate plasma glucosamine pharmacokinetics profiles after oral administration of crystalline glucosamine sulfate.
2006
Roda A., Sabatini L., Barbieri A., Guardigli M., Locatelli M., Violante F.S., et al. (2006). Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma. JOURNAL OF CHROMATOGRAPHY. B, 844, 119-126 [10.1016/j.jchromb.2006.07.013].
Roda A.; Sabatini L.; Barbieri A.; Guardigli M.; Locatelli M.; Violante F.S.; Rovati L.C.; Persiani S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/37905
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 49
social impact