This paper investigates effects of interstage water injection on the performance of a GE Frame 7EA gas turbine using aero-thermodynamic modeling. To accomplish this objective a computational code, written in Fortran 90 language and developed by DIEM – University of Bologna, has been used. The calculation procedure considers effects of evaporation of injected water within the compressor including droplets dynamics which are necessary in order to fully evaluate effects of wet compression on the gas turbine performance. The robustness of the computational code is demonstrated by evaluating stage-by-stage compressor performance and the overall gas turbine performance in presence of inlet evaporative fogging, overspray fogging and interstage water injection. The presented results show that water injection location influences compressor stage loading redistribution differently. The plausible explanations to the observed trends of various performance parameters are presented in the paper.

Bagnoli M., Bianchi M., Melino F., Peretto A., Spina P.R., Ingistov S., et al. (2006). Application of a computational code to simulate interstage injection effects on GE Frame 7EA gas turbine. NEW YORK : American Society of Mechanical Engineers (ASME).

Application of a computational code to simulate interstage injection effects on GE Frame 7EA gas turbine

BAGNOLI, MICHELE;BIANCHI, MICHELE;MELINO, FRANCESCO;PERETTO, ANTONIO;SPINA, PIER RUGGERO;
2006

Abstract

This paper investigates effects of interstage water injection on the performance of a GE Frame 7EA gas turbine using aero-thermodynamic modeling. To accomplish this objective a computational code, written in Fortran 90 language and developed by DIEM – University of Bologna, has been used. The calculation procedure considers effects of evaporation of injected water within the compressor including droplets dynamics which are necessary in order to fully evaluate effects of wet compression on the gas turbine performance. The robustness of the computational code is demonstrated by evaluating stage-by-stage compressor performance and the overall gas turbine performance in presence of inlet evaporative fogging, overspray fogging and interstage water injection. The presented results show that water injection location influences compressor stage loading redistribution differently. The plausible explanations to the observed trends of various performance parameters are presented in the paper.
2006
Proceedings of ASME Turbo Expo 2006
Bagnoli M., Bianchi M., Melino F., Peretto A., Spina P.R., Ingistov S., et al. (2006). Application of a computational code to simulate interstage injection effects on GE Frame 7EA gas turbine. NEW YORK : American Society of Mechanical Engineers (ASME).
Bagnoli M.; Bianchi M.; Melino F.; Peretto A.; Spina P.R.; Ingistov S.; Bhargava R.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/36223
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact