A screening method based on liquid chromatography–electrospray mass spectrometry for the simultaneous determination of six corticosteroids (betamethasone 17-valerate BM 17-V, beclomethasone BC,beclomethasone dipropionate BCDP, methylprednisolone MP, budesonide BD, flunisolide FN) was devel-oped in order to control their illegal use in cosmetic and natural products. Indeed, despite corticosteroids are banned in cosmetics, counterfeit products might be present on the market, representing a health hazard. Therefore, effective analytical methods are required to rapidly screen over the counter products in health care shops for counterfeit corticosteroids.The analytical method involves the employment of a Waters Synergy C18 column (150 mm × 2.0 mmI.D.) by using the following mobile phase: A (0.1% formic acid in acetonitrile), B (0.1% formic acid in water)in a linear gradient (from A–B 25:75, v/v to A–B 95:5, v/v in 30 min) at the flow rate of 0.3 mL/min. The detection was performed with an ion trap (IT) mass spectrometer in positive polarity, total ion current (TIC) and tandem mass modalities for qualitative purpose; single ion monitoring (SIM) mode was used for quantitative analysis on the ESI generated most abundant ion for each steroid.The method was fully validated in terms of precision, detection and quantification limits, linearity,recovery, and it was applied to the identification and quantification of corticosteroids in pharmaceutical formulations and cosmetic products. The mean recovery of BM 17-V, BC, BCDP, MP, BD and FN were foundto be 101.3, 101.5, 98.8, 98.9, 98.1, 99.0%, respectively. Limits of quantitation (LOQ) were comprised inthe range 29–95 ng/mL.To the best of our knowledge, for the first time this mix of glucocorticoids were simultaneously determined in cosmetic products by using a fully validated method. BMV, in its two isomeric forms BM 17-Vand BM 21-V, was found to be illegally present in one cream sample (A) with the total concentration levelof 0.036% (w/w).

Jessica Fiori, Vincenza andrisano (2014). LC–MS method for the simultaneous determination of six glucocorticoids in pharmaceutical formulations and counterfeit cosmetic products. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 91, 185-192 [10.1016/j.jpba.2013.12.026].

LC–MS method for the simultaneous determination of six glucocorticoids in pharmaceutical formulations and counterfeit cosmetic products

FIORI, JESSICA;ANDRISANO, VINCENZA
2014

Abstract

A screening method based on liquid chromatography–electrospray mass spectrometry for the simultaneous determination of six corticosteroids (betamethasone 17-valerate BM 17-V, beclomethasone BC,beclomethasone dipropionate BCDP, methylprednisolone MP, budesonide BD, flunisolide FN) was devel-oped in order to control their illegal use in cosmetic and natural products. Indeed, despite corticosteroids are banned in cosmetics, counterfeit products might be present on the market, representing a health hazard. Therefore, effective analytical methods are required to rapidly screen over the counter products in health care shops for counterfeit corticosteroids.The analytical method involves the employment of a Waters Synergy C18 column (150 mm × 2.0 mmI.D.) by using the following mobile phase: A (0.1% formic acid in acetonitrile), B (0.1% formic acid in water)in a linear gradient (from A–B 25:75, v/v to A–B 95:5, v/v in 30 min) at the flow rate of 0.3 mL/min. The detection was performed with an ion trap (IT) mass spectrometer in positive polarity, total ion current (TIC) and tandem mass modalities for qualitative purpose; single ion monitoring (SIM) mode was used for quantitative analysis on the ESI generated most abundant ion for each steroid.The method was fully validated in terms of precision, detection and quantification limits, linearity,recovery, and it was applied to the identification and quantification of corticosteroids in pharmaceutical formulations and cosmetic products. The mean recovery of BM 17-V, BC, BCDP, MP, BD and FN were foundto be 101.3, 101.5, 98.8, 98.9, 98.1, 99.0%, respectively. Limits of quantitation (LOQ) were comprised inthe range 29–95 ng/mL.To the best of our knowledge, for the first time this mix of glucocorticoids were simultaneously determined in cosmetic products by using a fully validated method. BMV, in its two isomeric forms BM 17-Vand BM 21-V, was found to be illegally present in one cream sample (A) with the total concentration levelof 0.036% (w/w).
2014
Jessica Fiori, Vincenza andrisano (2014). LC–MS method for the simultaneous determination of six glucocorticoids in pharmaceutical formulations and counterfeit cosmetic products. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 91, 185-192 [10.1016/j.jpba.2013.12.026].
Jessica Fiori; Vincenza andrisano
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/354916
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 34
social impact