The 24-hour changes in the complexity of ventricular repolarization in hemodialysis (HD) patients were quantified by principal component analysis (PCA) of the T wave. The effects of dialysis sessions leading to different plasma potassium levels ('Klow' and 'Khigh') were analyzed. Forty-six Holter recordings were collected from twelve patients. PCA was applied to the T waves extracted from each beat. Repolarization complexity was quantified by the ratio of the second to the first eigenvalue (PCA ratio). Hemodialysis caused a significant increase in the PCA ratio (+50% at the end of the sessions), which recovered to the basal value during the first hour post-dialysis. In the last two hours of dialysis PCA ratio was significantly higher in Klow sessions than in Khigh ones. Results show a significant HD-induced increase of the T wave complexity, strongly related to the therapy-induced potassium depletion.

Principal Component Analysis of the T Wave: 24 Hour Monitoring of Repolarization Complexity in Dialysis Patients / S. Severi; E. Grandi; G. Alessandrini; A. Santoro; S. Cavalcanti. - In: COMPUTERS IN CARDIOLOGY. - ISSN 0276-6574. - STAMPA. - 33:(2006), pp. 701-704. (Intervento presentato al convegno Computers in Cardiology 2006 tenutosi a Valencia, Spain nel 17-20 Sep 2006).

Principal Component Analysis of the T Wave: 24 Hour Monitoring of Repolarization Complexity in Dialysis Patients

SEVERI, STEFANO;GRANDI, ELEONORA;ALESSANDRINI, GIORGIA;SANTORO, ANTONIO;CAVALCANTI, SILVIO
2006

Abstract

The 24-hour changes in the complexity of ventricular repolarization in hemodialysis (HD) patients were quantified by principal component analysis (PCA) of the T wave. The effects of dialysis sessions leading to different plasma potassium levels ('Klow' and 'Khigh') were analyzed. Forty-six Holter recordings were collected from twelve patients. PCA was applied to the T waves extracted from each beat. Repolarization complexity was quantified by the ratio of the second to the first eigenvalue (PCA ratio). Hemodialysis caused a significant increase in the PCA ratio (+50% at the end of the sessions), which recovered to the basal value during the first hour post-dialysis. In the last two hours of dialysis PCA ratio was significantly higher in Klow sessions than in Khigh ones. Results show a significant HD-induced increase of the T wave complexity, strongly related to the therapy-induced potassium depletion.
2006
701
704
Principal Component Analysis of the T Wave: 24 Hour Monitoring of Repolarization Complexity in Dialysis Patients / S. Severi; E. Grandi; G. Alessandrini; A. Santoro; S. Cavalcanti. - In: COMPUTERS IN CARDIOLOGY. - ISSN 0276-6574. - STAMPA. - 33:(2006), pp. 701-704. (Intervento presentato al convegno Computers in Cardiology 2006 tenutosi a Valencia, Spain nel 17-20 Sep 2006).
S. Severi; E. Grandi; G. Alessandrini; A. Santoro; S. Cavalcanti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/34527
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact