Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed. Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured. There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous.

Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up / Savarino L.; Greco M.; Cenni E.; Cavasinni L.; Rotini R.; Baldini N.; Giunti A.. - In: JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME. - ISSN 0301-620X. - STAMPA. - 88:(2006), pp. 472-476. [10.1302/0301-620X.88B4.17333]

Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up.

BALDINI, NICOLA;GIUNTI, ARMANDO
2006

Abstract

Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed. Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured. There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous.
2006
Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up / Savarino L.; Greco M.; Cenni E.; Cavasinni L.; Rotini R.; Baldini N.; Giunti A.. - In: JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME. - ISSN 0301-620X. - STAMPA. - 88:(2006), pp. 472-476. [10.1302/0301-620X.88B4.17333]
Savarino L.; Greco M.; Cenni E.; Cavasinni L.; Rotini R.; Baldini N.; Giunti A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/28626
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 53
social impact