Balt (Montmorency, France) recently manufactured the Leo+Baby dedicated intracranial stent for arteries with a calibre between 1.5 and 3.10 mm. We describe a patient with a partially thrombosed giant sacciform aneurysm of the anterior communicating artery treated without success by surgery and coil embolization subsequently occluded by placement of a Leo+Baby stent (Balt, Montmorency, France). A 56-year-old man presented with a giant aneurysm in the anterior communicating artery region. Following successive surgical intervention and embolization procedures the patient was referred to us with a revascularized aneurysm measuring 15×9×8 cm. To stabilize the endovascular occlusion a combined treatment was scheduled with coil embolization and stent deployment after dual antiplatelet therapy started five days before the interventional procedure. Treatment was undertaken two weeks later under general anaesthesia and total heparinization. A microcatheter was inserted into the aneurysmal sac and four metal coils were released for a total of 61cm obtaining almost complete occlusion of the aneurysm from the circulation. A Leo+Baby stent (2.5×18 mm) was subsequently deployed across the aneurysm neck. At follow-up angiography two months later the aneurysm appeared substantially excluded from the arterial circulation except for a small portion in the neck. Six months later, four months after suspending antiplatelet therapy, follow-up angiography disclosed the complete exclusion of the aneurysm from the circulation. Deployment of the new ministent through the same microcatheter used to release the coils made the interventional procedure simpler and faster.

Dall'Olio M, Calbucci F, Fioravanti A, Bortolotti C, Cirillo L, Princiotta C, et al. (2013). Revascularized giant aneurysm of the anterior communicating artery after surgery and embolization, occluded by placement of a Leo+Baby intracranial stent. A case report. THE NEURORADIOLOGY JOURNAL, 26(3), 320-326.

Revascularized giant aneurysm of the anterior communicating artery after surgery and embolization, occluded by placement of a Leo+Baby intracranial stent. A case report.

CALBUCCI, FABIO;CIRILLO, LUIGI;LEONARDI, MARCO
2013

Abstract

Balt (Montmorency, France) recently manufactured the Leo+Baby dedicated intracranial stent for arteries with a calibre between 1.5 and 3.10 mm. We describe a patient with a partially thrombosed giant sacciform aneurysm of the anterior communicating artery treated without success by surgery and coil embolization subsequently occluded by placement of a Leo+Baby stent (Balt, Montmorency, France). A 56-year-old man presented with a giant aneurysm in the anterior communicating artery region. Following successive surgical intervention and embolization procedures the patient was referred to us with a revascularized aneurysm measuring 15×9×8 cm. To stabilize the endovascular occlusion a combined treatment was scheduled with coil embolization and stent deployment after dual antiplatelet therapy started five days before the interventional procedure. Treatment was undertaken two weeks later under general anaesthesia and total heparinization. A microcatheter was inserted into the aneurysmal sac and four metal coils were released for a total of 61cm obtaining almost complete occlusion of the aneurysm from the circulation. A Leo+Baby stent (2.5×18 mm) was subsequently deployed across the aneurysm neck. At follow-up angiography two months later the aneurysm appeared substantially excluded from the arterial circulation except for a small portion in the neck. Six months later, four months after suspending antiplatelet therapy, follow-up angiography disclosed the complete exclusion of the aneurysm from the circulation. Deployment of the new ministent through the same microcatheter used to release the coils made the interventional procedure simpler and faster.
2013
Dall'Olio M, Calbucci F, Fioravanti A, Bortolotti C, Cirillo L, Princiotta C, et al. (2013). Revascularized giant aneurysm of the anterior communicating artery after surgery and embolization, occluded by placement of a Leo+Baby intracranial stent. A case report. THE NEURORADIOLOGY JOURNAL, 26(3), 320-326.
Dall'Olio M; Calbucci F; Fioravanti A; Bortolotti C; Cirillo L; Princiotta C; Leonardi M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/274715
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact