In this study the analysis of di-tert-butyl peroxide decomposition in different organic solvents by screening calorimetry is proposed. Organic peroxides are liable to decompose exothermically at normal or high temperatures. The type of solvent changes the effects in the runaway behavior. Screening calorimetry data allow us to define the conditions and ranges of temperature and pressure involved. In the experimental apparatus used, the experiments are carried out safely even when there is a rapid and large increase in temperature and pressure. Screening calorimetry represents in this sense a first step in risk analysis studies and also a key in scaling up of processes. Screening calorimetry data have to be validated by experiments carried out in more complex calorimeters, similar to industrial reactors (adiabatic and reaction calorimeters), but the use of the TSu makes it possible to save time and reduce the number of experiments with laboratory scale calorimeters. In this paper a comparison between screening and adiabatic data for hydrogen n peroxide decomposition is shown.

MASCHIO G., LISTER D.G., CASSON V. (2010). Use Of Screening Analysis Calorimetry In The Study Of Peroxides Decomposition. milano : AIDIC Servizi [10.3303/CET1019057].

Use Of Screening Analysis Calorimetry In The Study Of Peroxides Decomposition

CASSON MORENO, VALERIA
2010

Abstract

In this study the analysis of di-tert-butyl peroxide decomposition in different organic solvents by screening calorimetry is proposed. Organic peroxides are liable to decompose exothermically at normal or high temperatures. The type of solvent changes the effects in the runaway behavior. Screening calorimetry data allow us to define the conditions and ranges of temperature and pressure involved. In the experimental apparatus used, the experiments are carried out safely even when there is a rapid and large increase in temperature and pressure. Screening calorimetry represents in this sense a first step in risk analysis studies and also a key in scaling up of processes. Screening calorimetry data have to be validated by experiments carried out in more complex calorimeters, similar to industrial reactors (adiabatic and reaction calorimeters), but the use of the TSu makes it possible to save time and reduce the number of experiments with laboratory scale calorimeters. In this paper a comparison between screening and adiabatic data for hydrogen n peroxide decomposition is shown.
2010
13th International Symposium on Loss Prevention and Safety Promotion in the Process Industries, Brugge (Belgium), 7-9 June 2010
347
352
MASCHIO G., LISTER D.G., CASSON V. (2010). Use Of Screening Analysis Calorimetry In The Study Of Peroxides Decomposition. milano : AIDIC Servizi [10.3303/CET1019057].
MASCHIO G.; LISTER D.G.; CASSON V.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/267140
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact