Purpose: To assess the degree of conversion (DC) at different levels of a resin-based luting agent used with different commercial posts. Methods: A resin-based luting agent (Variolink II) was light-cured in a simulated dowel space in combination with different fiber posts: GC Fiber Post (GC), DT Light Safety Lock (SL), RelyX Fiber Post (RX), Reforpost (RE), DT Light Post Illusion (LPI), FRC Postec Plus (FP), Radix (RA), Snowpost (SP), Dentin Post X (DP), Macro lock Illusion (MI), and Composipost (CP). After 24 hours, DC was assessed through micro-Raman analysis at the coronal, middle, and apical thirds. Two-way ANOVA and Tukey test were used for post-hoc comparisons (P< 0.05). Results: The results demonstrated that the post-type, dowel space level, and between-factor interaction were statistically significant (P< 0.001). Differences in DC were observed at different depths for RX, RE, LPI, SL, DP, MI and CP, decreasing from the coronal to the apical third. Although the resin-based luting agent should be able to polymerize in absence of light, a higher DC was found following light irradiation (with a decreasing effect from the coronal to the apical third). (Am J Dent 2012;25:17-20).

Navarra CO, Goracci C, Breschi L, Vichi A, Corciolani G, Cadenaro M, et al. (2012). Influence of post type on degree of conversion of a resin-based luting agent. AMERICAN JOURNAL OF DENTISTRY, 25(1), 17-20.

Influence of post type on degree of conversion of a resin-based luting agent

BRESCHI, LORENZO;
2012

Abstract

Purpose: To assess the degree of conversion (DC) at different levels of a resin-based luting agent used with different commercial posts. Methods: A resin-based luting agent (Variolink II) was light-cured in a simulated dowel space in combination with different fiber posts: GC Fiber Post (GC), DT Light Safety Lock (SL), RelyX Fiber Post (RX), Reforpost (RE), DT Light Post Illusion (LPI), FRC Postec Plus (FP), Radix (RA), Snowpost (SP), Dentin Post X (DP), Macro lock Illusion (MI), and Composipost (CP). After 24 hours, DC was assessed through micro-Raman analysis at the coronal, middle, and apical thirds. Two-way ANOVA and Tukey test were used for post-hoc comparisons (P< 0.05). Results: The results demonstrated that the post-type, dowel space level, and between-factor interaction were statistically significant (P< 0.001). Differences in DC were observed at different depths for RX, RE, LPI, SL, DP, MI and CP, decreasing from the coronal to the apical third. Although the resin-based luting agent should be able to polymerize in absence of light, a higher DC was found following light irradiation (with a decreasing effect from the coronal to the apical third). (Am J Dent 2012;25:17-20).
2012
Navarra CO, Goracci C, Breschi L, Vichi A, Corciolani G, Cadenaro M, et al. (2012). Influence of post type on degree of conversion of a resin-based luting agent. AMERICAN JOURNAL OF DENTISTRY, 25(1), 17-20.
Navarra CO; Goracci C; Breschi L; Vichi A; Corciolani G; Cadenaro M; Ferrari M
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/262975
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact