A new enantioselective HPLC method was developed for the resolution and determination of the enantiomers of methorphan, dextromethorphan (DXM) and levomethorphan (LVM), on a Chiralcel OJ column (250 mm × 4.6mm I.D.). The resolution of DXM and LVM was obtained using a mobile phase consisting of (n-hexane)-(2-propanol)-diethylamine (70:30:0.1, v/v/v) at a flow rate of 0.5 mL min(-1). The enantioselective method was found to be selective (α=1.92) and sensitive (LOD=2.8 μg mL(-1) for both DXM and LVM). The method was coupled with electronic circular dichroism (CD), allowing the determination of the elution order on the basis of the sign of CD signals of the single enantiomers at 285 nm (positive for DXM, negative for LVM). Under the optimized conditions, the validated method was applied to the identification and quantitation of the enantiomers of methorphan in samples of different sources of illicit drugs of abuse (heroin). DXM was found in eight seized samples of street heroin; two of these samples, for which the DXM content was found to be over 5% (w/w) and exceeding a 10% (w/w) ratio with respect to diacetylmorphine, were the cause of two deaths for overdose due to acute narcotism.

Daniele Tedesco, Anna Maria Di Pietra, Francesca Rossi, Marco Garagnani, Elia Del Borrello, Carlo Bertucci, et al. (2013). Determination of dextromethorphan and levomethorphan in seized heroin samples by enantioselective HPLC and electronic CD. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 81-82, 76-79 [10.1016/j.jpba.2013.03.024].

Determination of dextromethorphan and levomethorphan in seized heroin samples by enantioselective HPLC and electronic CD

TEDESCO, DANIELE;DI PIETRA, ANNA MARIA;ROSSI, FRANCESCA;GARAGNANI, MARCO;DEL BORRELLO, ELIA;BERTUCCI, CARLO;ANDRISANO, VINCENZA
2013

Abstract

A new enantioselective HPLC method was developed for the resolution and determination of the enantiomers of methorphan, dextromethorphan (DXM) and levomethorphan (LVM), on a Chiralcel OJ column (250 mm × 4.6mm I.D.). The resolution of DXM and LVM was obtained using a mobile phase consisting of (n-hexane)-(2-propanol)-diethylamine (70:30:0.1, v/v/v) at a flow rate of 0.5 mL min(-1). The enantioselective method was found to be selective (α=1.92) and sensitive (LOD=2.8 μg mL(-1) for both DXM and LVM). The method was coupled with electronic circular dichroism (CD), allowing the determination of the elution order on the basis of the sign of CD signals of the single enantiomers at 285 nm (positive for DXM, negative for LVM). Under the optimized conditions, the validated method was applied to the identification and quantitation of the enantiomers of methorphan in samples of different sources of illicit drugs of abuse (heroin). DXM was found in eight seized samples of street heroin; two of these samples, for which the DXM content was found to be over 5% (w/w) and exceeding a 10% (w/w) ratio with respect to diacetylmorphine, were the cause of two deaths for overdose due to acute narcotism.
2013
Daniele Tedesco, Anna Maria Di Pietra, Francesca Rossi, Marco Garagnani, Elia Del Borrello, Carlo Bertucci, et al. (2013). Determination of dextromethorphan and levomethorphan in seized heroin samples by enantioselective HPLC and electronic CD. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 81-82, 76-79 [10.1016/j.jpba.2013.03.024].
Daniele Tedesco; Anna Maria Di Pietra; Francesca Rossi; Marco Garagnani; Elia Del Borrello; Carlo Bertucci; Vincenza Andrisano
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/223291
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact