Purpose: The aim of this study was to analyse factors predicting the diagnostic accuracy of computed tomography (CT)-guided transthoracic fine-needle aspiration (TTFNA) for solid noncalcified, subsolid and mixed pulmonary nodules, with particular attention to those responsible for false negative results with a view to suggesting a method for their correction. Materials and methods: From January 2007 to March 2010, we retrospectively reviewed the CT images of 198 patients of both sexes (124 males and 74 females; mean age, 70 years; range age, 44-90) used for the guidance of TTFNA of pulmonary nodules. Aspects considered were: lesion size and density, distance from the pleura, and lesion site. Multiplanar reformatted images (MPR) were retrospectively obtained in the sagittal and axial oblique planes relative to needle orientation. Results: The overall diagnostic accuracy of TTFNA CTguided biopsy was 86% for nodules between 0.7 and 3 cm, 83.3% for those between 0.7 and 1.5 cm, and 92% for those between 2 and 3 cm. Accuracy was 95.1% for solid pulmonary nodules, 84.6% for mixed nodules, and 66.6% for subsolid nodules. The diagnostic accuracy of CT-guided TTFNA in relation to the distance between the nodule and the pleural plane was 95.6% for lesions adhering to the pleura and 83.5% for central ones. The diagnostic accuracy was 84.2% for the pulmonary upper lobe nodules, 85.3% for the lower lobe and 90.9% for those in the lingula and middle lobe. In 75% of false negative and inadequate/insufficient cases the needle was found to lie outside the lesion, after reconstruction of the needle path by MPR. Conclusions: The positive predictive factors of CT-guided TTFNA are related to the nodule size, density and distance from the pleural plane. The most common negative predictive factor of CT-guided TTFNA is the wrong position of the needle tip, as observed in the sagittal and axial oblique sections of the MPR reconstructions. The diagnostic accuracy of CT-guided TTFNA can therefore be improved by using the MPR technique to plan the needle path during the FNA procedure. © 2013 Springer-Verlag.

Predictive factors of diagnostic accuracy of CT guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules

ARDIZZONI, ANDREA;ZOMPATORI, MAURIZIO;
2013

Abstract

Purpose: The aim of this study was to analyse factors predicting the diagnostic accuracy of computed tomography (CT)-guided transthoracic fine-needle aspiration (TTFNA) for solid noncalcified, subsolid and mixed pulmonary nodules, with particular attention to those responsible for false negative results with a view to suggesting a method for their correction. Materials and methods: From January 2007 to March 2010, we retrospectively reviewed the CT images of 198 patients of both sexes (124 males and 74 females; mean age, 70 years; range age, 44-90) used for the guidance of TTFNA of pulmonary nodules. Aspects considered were: lesion size and density, distance from the pleura, and lesion site. Multiplanar reformatted images (MPR) were retrospectively obtained in the sagittal and axial oblique planes relative to needle orientation. Results: The overall diagnostic accuracy of TTFNA CTguided biopsy was 86% for nodules between 0.7 and 3 cm, 83.3% for those between 0.7 and 1.5 cm, and 92% for those between 2 and 3 cm. Accuracy was 95.1% for solid pulmonary nodules, 84.6% for mixed nodules, and 66.6% for subsolid nodules. The diagnostic accuracy of CT-guided TTFNA in relation to the distance between the nodule and the pleural plane was 95.6% for lesions adhering to the pleura and 83.5% for central ones. The diagnostic accuracy was 84.2% for the pulmonary upper lobe nodules, 85.3% for the lower lobe and 90.9% for those in the lingula and middle lobe. In 75% of false negative and inadequate/insufficient cases the needle was found to lie outside the lesion, after reconstruction of the needle path by MPR. Conclusions: The positive predictive factors of CT-guided TTFNA are related to the nodule size, density and distance from the pleural plane. The most common negative predictive factor of CT-guided TTFNA is the wrong position of the needle tip, as observed in the sagittal and axial oblique sections of the MPR reconstructions. The diagnostic accuracy of CT-guided TTFNA can therefore be improved by using the MPR technique to plan the needle path during the FNA procedure. © 2013 Springer-Verlag.
2013
De Filippo, Massimo; Saba, Luca; Concari, Giorgio; Nizzoli, Rita; Ferrari, Lilia; Tiseo, Marcello; Ardizzoni, Andrea; Sverzellati, Nicola; Paladini, Ilaria; Ganazzoli, Chiara; Sconfienza, Luca Maria; Carrafiello, Giampaolo; Brunese, Luca; Genovese, Eugenio Annibale; Ampollini, Luca; Carbognani, Paolo; Rusca, Michele; Zompatori, Maurizio; Rossi, Cristina
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/191939
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 22
  • Scopus 50
  • ???jsp.display-item.citation.isi??? 42
social impact