In this paper one of the procedures proposed in literature for the design of viscous dampers to be inserted in existing buildings is examined and extended to 3D eccentric buildings. This procedure is based on an energy criterion for the determination of the damping ratio and accounts for the nonlinear behavior of the structure through pushover analysis. The proposed procedure has been verified through a case study characterized by a six story RC building dimensioned only for gravity loads and rehabilitated with fluid-viscous dampers. This building has been analyzed both with the procedure proposed in literature for plan buildings, and with the extended one. Moreover, the importance of considering the higher modes has been investigated. The effectiveness of the design procedure has been then evaluated through the comparison with nonlinear dynamic analyses.

LUCA LANDI, PIER PAOLO DIOTALLEVI, GIULIA CASTELLARI (2013). DESIGN OF VISCOUS DAMPERS FOR THE SEISMIC RETROFIT OF PLAN-ASYMMETRIC STRUCTURES. Singapore : Research Publishing Services (www.rpsonline.com.sg) [10.3850/978-981-07-5354-2St-169-493].

DESIGN OF VISCOUS DAMPERS FOR THE SEISMIC RETROFIT OF PLAN-ASYMMETRIC STRUCTURES

LANDI, LUCA;DIOTALLEVI, PIER PAOLO;
2013

Abstract

In this paper one of the procedures proposed in literature for the design of viscous dampers to be inserted in existing buildings is examined and extended to 3D eccentric buildings. This procedure is based on an energy criterion for the determination of the damping ratio and accounts for the nonlinear behavior of the structure through pushover analysis. The proposed procedure has been verified through a case study characterized by a six story RC building dimensioned only for gravity loads and rehabilitated with fluid-viscous dampers. This building has been analyzed both with the procedure proposed in literature for plan buildings, and with the extended one. Moreover, the importance of considering the higher modes has been investigated. The effectiveness of the design procedure has been then evaluated through the comparison with nonlinear dynamic analyses.
2013
New Developments in Structural Engineering and Construction
1755
1760
LUCA LANDI, PIER PAOLO DIOTALLEVI, GIULIA CASTELLARI (2013). DESIGN OF VISCOUS DAMPERS FOR THE SEISMIC RETROFIT OF PLAN-ASYMMETRIC STRUCTURES. Singapore : Research Publishing Services (www.rpsonline.com.sg) [10.3850/978-981-07-5354-2St-169-493].
LUCA LANDI; PIER PAOLO DIOTALLEVI; GIULIA CASTELLARI
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/189143
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact