This paper describes the results from a series of shacking table tests conducted on a fullscale reinforced concrete building. The specimen was a 3-storey structural system composed of squat cast-in-situ sandwich concrete walls with 5.50 m length, 4.10 m width and 8.25 m height. Shaking table tests were performed to validate the theoretical formulations which had been already developed by the authors in order to predict the seismic capacity of the tested structural systems. Both white noise and seismic tests were performed increasing the seismic intensity between 0.05 to 1.2 g. At the end of the experimental campaign, the building was essentially undamaged. From the white noise tests, a slight increase in the fundamental period was found, indicating some degradation. Although a meaningful interpretation of the test results in still under development, the structural system showed an impressive seismic capacity.
Ilaria Ricci, Michele Palermo, Stefano Silvestri, Giada Gasparini, Tomaso Trombetti, Dora Foti, et al. (2013). Shake Table Response of a Full-Scale 3-Storey Building Composed of Thin Reinforced Concrete Sandwich walls. Ottawa : Advanced Engineering Solutions [AES.COM].
Shake Table Response of a Full-Scale 3-Storey Building Composed of Thin Reinforced Concrete Sandwich walls
RICCI, ILARIA;PALERMO, MICHELE;SILVESTRI, STEFANO;GASPARINI, GIADA;TROMBETTI, TOMASO;
2013
Abstract
This paper describes the results from a series of shacking table tests conducted on a fullscale reinforced concrete building. The specimen was a 3-storey structural system composed of squat cast-in-situ sandwich concrete walls with 5.50 m length, 4.10 m width and 8.25 m height. Shaking table tests were performed to validate the theoretical formulations which had been already developed by the authors in order to predict the seismic capacity of the tested structural systems. Both white noise and seismic tests were performed increasing the seismic intensity between 0.05 to 1.2 g. At the end of the experimental campaign, the building was essentially undamaged. From the white noise tests, a slight increase in the fundamental period was found, indicating some degradation. Although a meaningful interpretation of the test results in still under development, the structural system showed an impressive seismic capacity.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.