The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. Methods. Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. Results. VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and 9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). Conclusion. VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.

Improved Quantification of Left Ventricular Volumes and Mass Based On Endocardial and Epicardial Surface Detection From Cardiac MR Images Using Level Set Models / C. Corsi; C. Lamberti; O. Catalano; P. MacEneaney; D. Bardo; R. M. Lang; E. G. Caiani; V. Mor-Avi. - In: JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE. - ISSN 1097-6647. - STAMPA. - 7(3):(2005), pp. 595-602. [10.1081/JCMR-200060624]

Improved Quantification of Left Ventricular Volumes and Mass Based On Endocardial and Epicardial Surface Detection From Cardiac MR Images Using Level Set Models

CORSI, CRISTIANA;LAMBERTI, CLAUDIO;
2005

Abstract

The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. Methods. Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. Results. VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and 9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). Conclusion. VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.
2005
Improved Quantification of Left Ventricular Volumes and Mass Based On Endocardial and Epicardial Surface Detection From Cardiac MR Images Using Level Set Models / C. Corsi; C. Lamberti; O. Catalano; P. MacEneaney; D. Bardo; R. M. Lang; E. G. Caiani; V. Mor-Avi. - In: JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE. - ISSN 1097-6647. - STAMPA. - 7(3):(2005), pp. 595-602. [10.1081/JCMR-200060624]
C. Corsi; C. Lamberti; O. Catalano; P. MacEneaney; D. Bardo; R. M. Lang; E. G. Caiani; V. Mor-Avi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/16230
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact