In this paper the insulation resistances of the concrete structures of a high-speed rail transit system viaduct are analysed by means of an equivalent circuit. It is shown that the insulation resistances between a span and its respective piers and between adjacent spans depend on the earth wire to rebar resistance of the spans. The insulation resistances measured during the construction stages of the Ticino viaduct of the Italian ac high-speed line are used to estimate the earth wire to rebar resistance in three sections of the viaduct with different characteristics. The variation of the earth wire to rebar resistance along the viaduct can be related to the type, extension and progressive installation of metallic fixed structures in the spans. A good agreement between the viaduct insulation resistances calculated with the equivalent circuit and the measurements is found. An assessment of the stray current interference on a viaduct span is made with reference to the standard EN 50122-2:2010.

Analysis of the insulation resistances of a high-speed rail transit system viaduct for the assessment of stray current interference. Part 2: Modelling / Leonardo Sandrolini. - In: ELECTRIC POWER SYSTEMS RESEARCH. - ISSN 0378-7796. - STAMPA. - 103:(2013), pp. 248-254. [10.1016/j.epsr.2013.04.012]

Analysis of the insulation resistances of a high-speed rail transit system viaduct for the assessment of stray current interference. Part 2: Modelling

SANDROLINI, LEONARDO
2013

Abstract

In this paper the insulation resistances of the concrete structures of a high-speed rail transit system viaduct are analysed by means of an equivalent circuit. It is shown that the insulation resistances between a span and its respective piers and between adjacent spans depend on the earth wire to rebar resistance of the spans. The insulation resistances measured during the construction stages of the Ticino viaduct of the Italian ac high-speed line are used to estimate the earth wire to rebar resistance in three sections of the viaduct with different characteristics. The variation of the earth wire to rebar resistance along the viaduct can be related to the type, extension and progressive installation of metallic fixed structures in the spans. A good agreement between the viaduct insulation resistances calculated with the equivalent circuit and the measurements is found. An assessment of the stray current interference on a viaduct span is made with reference to the standard EN 50122-2:2010.
2013
Analysis of the insulation resistances of a high-speed rail transit system viaduct for the assessment of stray current interference. Part 2: Modelling / Leonardo Sandrolini. - In: ELECTRIC POWER SYSTEMS RESEARCH. - ISSN 0378-7796. - STAMPA. - 103:(2013), pp. 248-254. [10.1016/j.epsr.2013.04.012]
Leonardo Sandrolini
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/152200
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 13
social impact