A sound source and a microphone grid are used for measuring a set of impulse responses with the purpose of estimating the in-situ acoustical characteristics of noise barriers (sound reflection and airborne sound insulation) following the CEN/TS 1793-5 European standard guidelines as improved by the European project QUIESST. The impulse responses are measured using MLS (Maximum Length Sequence) and Swept-sine signals. The acoustical characteristics of the noise barrier, obtained using the two signals, are generally equivalent, but in some critical measurement conditions a discrepancy can be found. Differences and advantages between measurements, obtained by means of MLS or Swept-sine signals, are analyzed and discussed in this paper.

Guidorzi P., Garai M. (2013). Impulse responses measured with MLS or Swept-sine signals: a comparison between the two methods applied to noise barriers measurements. Roma : AES Italy.

Impulse responses measured with MLS or Swept-sine signals: a comparison between the two methods applied to noise barriers measurements

GUIDORZI, PAOLO;GARAI, MASSIMO
2013

Abstract

A sound source and a microphone grid are used for measuring a set of impulse responses with the purpose of estimating the in-situ acoustical characteristics of noise barriers (sound reflection and airborne sound insulation) following the CEN/TS 1793-5 European standard guidelines as improved by the European project QUIESST. The impulse responses are measured using MLS (Maximum Length Sequence) and Swept-sine signals. The acoustical characteristics of the noise barrier, obtained using the two signals, are generally equivalent, but in some critical measurement conditions a discrepancy can be found. Differences and advantages between measurements, obtained by means of MLS or Swept-sine signals, are analyzed and discussed in this paper.
2013
Proceedings of 134th AES Convention
8914-01
8914-10
Guidorzi P., Garai M. (2013). Impulse responses measured with MLS or Swept-sine signals: a comparison between the two methods applied to noise barriers measurements. Roma : AES Italy.
Guidorzi P.; Garai M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/145916
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni