The n_TOF collaboration operates a Total Absorption Calorimeter (TAC) [1] for measuring neu- tron capture cross-sections of low-mass and/or radioactive samples. The results obtained with the TAC have led to a substantial improvement of the capture cross sections of 237Np and 240Pu [2]. The experience acquired during the first measurements has allowed us to optimize the performance of the TAC and to improve the capture signal to background ratio, thus opening the way to more complex and demanding measurements on rare radioactive materials. The new design has been reached by a series of detailed Monte Carlo simulations of complete experiments and dedicated test measurements. The new capture setup will be presented and the main achievements highlighted.

Mendoza E., Becares V., Casado A., Cano-Ott D., Fernandez-Ordonez M., Gonzalez-Romero E., et al. (2011). Improved Neutron Capture Cross Section Measurements with the n_TOF Total Absorption Calorimeter. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 59, 1813-1-1813-4 [10.3938/jkps.59.1813].

Improved Neutron Capture Cross Section Measurements with the n_TOF Total Absorption Calorimeter

MASSIMI, CRISTIAN;VANNINI, GIANNI;
2011

Abstract

The n_TOF collaboration operates a Total Absorption Calorimeter (TAC) [1] for measuring neu- tron capture cross-sections of low-mass and/or radioactive samples. The results obtained with the TAC have led to a substantial improvement of the capture cross sections of 237Np and 240Pu [2]. The experience acquired during the first measurements has allowed us to optimize the performance of the TAC and to improve the capture signal to background ratio, thus opening the way to more complex and demanding measurements on rare radioactive materials. The new design has been reached by a series of detailed Monte Carlo simulations of complete experiments and dedicated test measurements. The new capture setup will be presented and the main achievements highlighted.
2011
Mendoza E., Becares V., Casado A., Cano-Ott D., Fernandez-Ordonez M., Gonzalez-Romero E., et al. (2011). Improved Neutron Capture Cross Section Measurements with the n_TOF Total Absorption Calorimeter. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 59, 1813-1-1813-4 [10.3938/jkps.59.1813].
Mendoza E.;Becares V.;Casado A.;Cano-Ott D.;Fernandez-Ordonez M.;Gonzalez-Romero E.;Guerrero C.;Martinez T.;Vidriales J. J.;Andrzejewski J.;Marganiec ...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/140009
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact