Abstract The aim of this paper is to clarify some physicalemechanical aspects involved in the carbon dioxide angiography procedure (CO2 angiography), with a particular attention to a possible damage of the vascular wall. CO2 angiography is widely used on patients with iodine intolerance. The injection of a gaseous element, in most cases manually performed, requires a long training period. Automatic systems allow better control of the injection and the study of the mechanical behaviour of the gas. CO2 injections have been studied by using manual and automatic systems. Pressures, flows and jet shapes have been monitored by using a cardiovascular mock. Photographic images of liquid and gaseous jet have been recorded in different conditions, and the vascular pressure rises during injection have been monitored. The shape of the liquid jet during the catheter washing phase is straight in the catheter direction and there is no jet during gas injection. Gas bubbles are suddenly formed at the catheter’s hole and move upwards: buoyancy is the only governing phenomenon and no bubbles fragmentation is detected. The pressure rise in the vessel depends on the injection pressure and volume and in some cases of manual injection it may double the basal vascular pressure values. CO2 angiography is a powerful and safe procedure which diffusion will certainly increase, although some aspects related to gas injection and chamber filling are not jet well known. The use of an automatic system permits better results, shorter training period and limitation of vascular wall damage risk.

Mechanical aspects of CO2 angiography

CORAZZA, IVAN;ROSSI, PIER LUCA;FELICIANI, GIACOMO;ZANNOLI, ROMANO
2013

Abstract

Abstract The aim of this paper is to clarify some physicalemechanical aspects involved in the carbon dioxide angiography procedure (CO2 angiography), with a particular attention to a possible damage of the vascular wall. CO2 angiography is widely used on patients with iodine intolerance. The injection of a gaseous element, in most cases manually performed, requires a long training period. Automatic systems allow better control of the injection and the study of the mechanical behaviour of the gas. CO2 injections have been studied by using manual and automatic systems. Pressures, flows and jet shapes have been monitored by using a cardiovascular mock. Photographic images of liquid and gaseous jet have been recorded in different conditions, and the vascular pressure rises during injection have been monitored. The shape of the liquid jet during the catheter washing phase is straight in the catheter direction and there is no jet during gas injection. Gas bubbles are suddenly formed at the catheter’s hole and move upwards: buoyancy is the only governing phenomenon and no bubbles fragmentation is detected. The pressure rise in the vessel depends on the injection pressure and volume and in some cases of manual injection it may double the basal vascular pressure values. CO2 angiography is a powerful and safe procedure which diffusion will certainly increase, although some aspects related to gas injection and chamber filling are not jet well known. The use of an automatic system permits better results, shorter training period and limitation of vascular wall damage risk.
2013
I. Corazza; P.L. Rossi; G. Feliciani; L. Pisani; S. Zannoli; R. Zannoli
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/133103
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact