Guided Wave based Structural Health Monitoring greatly benefits from directional scanning. In contrast with conventional phased array approaches, the novel frequencybased beam steering concept and the associated signal processing presented in this work enable imaging of two-dimensional (2D) areas through the output of a single, dual channel sensor.
Spectrogram remapping based imaging for spiral shaped frequency steerable acoustic transducers / E. Baravelli; L. De Marchi; M. Ruzzene; N. Speciale. - (2011), pp. 967-970. (Intervento presentato al convegno 2011 IEEE International Ultrasonics Symposium tenutosi a Caribe Royale, Orlando, Florida, USA nel October 18-21, 2011) [10.1109/ULTSYM.2011.0237].
Spectrogram remapping based imaging for spiral shaped frequency steerable acoustic transducers
BARAVELLI, EMANUELE;DE MARCHI, LUCA;SPECIALE, NICOLO'ATTILIO
2011
Abstract
Guided Wave based Structural Health Monitoring greatly benefits from directional scanning. In contrast with conventional phased array approaches, the novel frequencybased beam steering concept and the associated signal processing presented in this work enable imaging of two-dimensional (2D) areas through the output of a single, dual channel sensor.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.