ABSTRACT Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instruments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.

Dagna A, Arciola CR, Visai L, Selan L, Colombo M, Bianchi S, et al. (2012). Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 35(10), 826-831 [10.5301/ijao.5000160].

Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation

ARCIOLA, CARLA RENATA;
2012

Abstract

ABSTRACT Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instruments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.
2012
Dagna A, Arciola CR, Visai L, Selan L, Colombo M, Bianchi S, et al. (2012). Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 35(10), 826-831 [10.5301/ijao.5000160].
Dagna A; Arciola CR; Visai L; Selan L; Colombo M; Bianchi S; Poggio C
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/129228
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact