ABSTRACT Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instruments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.

Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation / Dagna A; Arciola CR; Visai L; Selan L; Colombo M; Bianchi S; Poggio C. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - STAMPA. - 35:10(2012), pp. 826-831. [10.5301/ijao.5000160]

Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation

ARCIOLA, CARLA RENATA;
2012

Abstract

ABSTRACT Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instruments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.
2012
Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation / Dagna A; Arciola CR; Visai L; Selan L; Colombo M; Bianchi S; Poggio C. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - STAMPA. - 35:10(2012), pp. 826-831. [10.5301/ijao.5000160]
Dagna A; Arciola CR; Visai L; Selan L; Colombo M; Bianchi S; Poggio C
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/129228
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact