BACKGROUND: Implantable cardioverter-defibrillator (ICD) studies in patients with coronary artery disease report higher risk of ventricular tachycardia/fibrillation (VT/VF) early post-implant, potentially related to local proarrhythmic effects of ICD leads. OBJECTIVE: To characterize early and long-term risk of ICD discharge for VT/VF in a large hypertrophic cardiomyopathy (HCM) cohort. METHODS: By using HCM multicenter registry data, we compared long-term risk of VT/VF subsequent to an early post-implant period (a priori defined as within 3 months of implant) between patients with or without VT/VF within 3 months after ICD implantation. RESULTS: Over a median follow-up of 4.3 years, 109 of 506 (22%) patients with HCM who received ICDs received at least 1 ICD discharge for VT/VF. Risk of first ICD discharge for VT/VF was highest in the first year post-implant (10.8% per person-year; 95% confidence interval 7.9-13.8) and particularly in the first 3 months (17.0% per person-year; 95% confidence interval 9.8-24.3). Patients with early VT/VF (≤3 months post-implant) were older, and more commonly had secondary prevention ICDs following cardiac arrest or systolic dysfunction (end-stage HCM with ejection fraction<50%). Only 2 of 247 (0.7%) patients with primary prevention ICDs and preserved systolic function had early VT/VF. Patients with VT/VF early post-implant (≤3 months) had more than 5-fold higher risk for future VT/VF during long-term follow-up compared with patients without early VT/VF (adjusted hazard ratio 5.4; 95% confidence interval 2.3-12.6). CONCLUSIONS: High-risk patients with HCM and VT/VF early after ICD implantation are particularly prone to subsequent VT/VF throughout follow-up. Early ICD interventions for VT/VF are largely confined to patients with prior cardiac arrest or systolic dysfunction and therefore more likely driven by higher arrhythmic risk rather than lead-related proarrhythmia.

Ventricular tachycardia/fibrillation early after defibrillator implantation in patients with hypertrophic cardiomyopathy is explained by a high risk subgroup of patients / Alsheikh-Ali AA; Link MS; Semsarian C; Shen WK; Mark Estes NA 3rd; Maron MS; Haas TS; Formisano F; Boriani G; Spirito P; Maron BJ.. - In: HEART RHYTHM. - ISSN 1547-5271. - STAMPA. - 10:2(2013), pp. 214-218. [10.1016/j.hrthm.2012.10.003]

Ventricular tachycardia/fibrillation early after defibrillator implantation in patients with hypertrophic cardiomyopathy is explained by a high risk subgroup of patients.

BORIANI, GIUSEPPE;
2013

Abstract

BACKGROUND: Implantable cardioverter-defibrillator (ICD) studies in patients with coronary artery disease report higher risk of ventricular tachycardia/fibrillation (VT/VF) early post-implant, potentially related to local proarrhythmic effects of ICD leads. OBJECTIVE: To characterize early and long-term risk of ICD discharge for VT/VF in a large hypertrophic cardiomyopathy (HCM) cohort. METHODS: By using HCM multicenter registry data, we compared long-term risk of VT/VF subsequent to an early post-implant period (a priori defined as within 3 months of implant) between patients with or without VT/VF within 3 months after ICD implantation. RESULTS: Over a median follow-up of 4.3 years, 109 of 506 (22%) patients with HCM who received ICDs received at least 1 ICD discharge for VT/VF. Risk of first ICD discharge for VT/VF was highest in the first year post-implant (10.8% per person-year; 95% confidence interval 7.9-13.8) and particularly in the first 3 months (17.0% per person-year; 95% confidence interval 9.8-24.3). Patients with early VT/VF (≤3 months post-implant) were older, and more commonly had secondary prevention ICDs following cardiac arrest or systolic dysfunction (end-stage HCM with ejection fraction<50%). Only 2 of 247 (0.7%) patients with primary prevention ICDs and preserved systolic function had early VT/VF. Patients with VT/VF early post-implant (≤3 months) had more than 5-fold higher risk for future VT/VF during long-term follow-up compared with patients without early VT/VF (adjusted hazard ratio 5.4; 95% confidence interval 2.3-12.6). CONCLUSIONS: High-risk patients with HCM and VT/VF early after ICD implantation are particularly prone to subsequent VT/VF throughout follow-up. Early ICD interventions for VT/VF are largely confined to patients with prior cardiac arrest or systolic dysfunction and therefore more likely driven by higher arrhythmic risk rather than lead-related proarrhythmia.
2013
Ventricular tachycardia/fibrillation early after defibrillator implantation in patients with hypertrophic cardiomyopathy is explained by a high risk subgroup of patients / Alsheikh-Ali AA; Link MS; Semsarian C; Shen WK; Mark Estes NA 3rd; Maron MS; Haas TS; Formisano F; Boriani G; Spirito P; Maron BJ.. - In: HEART RHYTHM. - ISSN 1547-5271. - STAMPA. - 10:2(2013), pp. 214-218. [10.1016/j.hrthm.2012.10.003]
Alsheikh-Ali AA; Link MS; Semsarian C; Shen WK; Mark Estes NA 3rd; Maron MS; Haas TS; Formisano F; Boriani G; Spirito P; Maron BJ.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/128803
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 6
social impact