The interconnections between Large Hadron Collider (LHC) main dipole and quadrupole magnets are made of soldered joints of two superconducting cables stabilized by a copper bus bar. The 2008 incident revealed the possible presence of defects in the interconnections of the 13 kA circuits that could lead to unprotected resistive transitions. Since then thorough experimental and numerical investigations were undertaken to determine the safe operating conditions for the LHC. This paper reports the analysis of experimental tests reproducing defective interconnections between main quadrupole magnets. A thermo-electromagnetic model was developed taking into account the complicated sample geometry. Close attention was paid to the physical description of the heat transfer towards helium, one of the main unknown parameters. The simulation results are reported in comparison with the measurements in case of static He I cooling bath. The outcome of this study constitutes a useful input to improve the stability assessment of the 13 kA bus bars interconnections.

P. P. Granieri, M. Casali, M. Bianchi, M. Breschi, L. Bottura, G. Willering (2012). Analysis of defective interconnections of the 13 kA LHC superconducting bus bars. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 22(3), 1-4 [10.1109/TASC.2011.2180275].

Analysis of defective interconnections of the 13 kA LHC superconducting bus bars

CASALI, MARCO;BRESCHI, MARCO;
2012

Abstract

The interconnections between Large Hadron Collider (LHC) main dipole and quadrupole magnets are made of soldered joints of two superconducting cables stabilized by a copper bus bar. The 2008 incident revealed the possible presence of defects in the interconnections of the 13 kA circuits that could lead to unprotected resistive transitions. Since then thorough experimental and numerical investigations were undertaken to determine the safe operating conditions for the LHC. This paper reports the analysis of experimental tests reproducing defective interconnections between main quadrupole magnets. A thermo-electromagnetic model was developed taking into account the complicated sample geometry. Close attention was paid to the physical description of the heat transfer towards helium, one of the main unknown parameters. The simulation results are reported in comparison with the measurements in case of static He I cooling bath. The outcome of this study constitutes a useful input to improve the stability assessment of the 13 kA bus bars interconnections.
2012
P. P. Granieri, M. Casali, M. Bianchi, M. Breschi, L. Bottura, G. Willering (2012). Analysis of defective interconnections of the 13 kA LHC superconducting bus bars. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 22(3), 1-4 [10.1109/TASC.2011.2180275].
P. P. Granieri; M. Casali; M. Bianchi; M. Breschi; L. Bottura; G. Willering
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/128323
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact