Abstract BACKGROUND: Subcutaneous almost substituted subpectoral approach of implantable cardioverter-defibrillator (ICD) implantation as a less invasive surgical technique. However, the impact of this change in placement site on procedure-related shoulder impairment is poorly understood. METHODS: Candidates for ICD implantation were prospectively evaluated at baseline, 2-weeks and 3-months after the procedure. Assessment of shoulder function included: Constant Score, Numeric Rating Scale (NRS) for pain and the Disability of the Arm, Shoulder and Hand (DASH) scoring method. The Short Form-36 (SF-36) questionnaire was adopted for quality of life. RESULTS: Fifty consecutive patients were enrolled (21 single-chamber, 5 dual-chamber and 24 biventricular ICD). Significant changes in the short term were observed: physical component summary (regarding SF-36) decreased from 44.5±9.1 to 41.8±11.4 (p=0.016), patients with NRS >1 increased from 14% to 44% (p<0.001), DASH score increased from 1.29 [interquartile range 0.00-10.34] to 30.60 [interquartile range 12.93-46.34] (p<0.001). Notably, only the shoulder ipsilateral to implantation site presented a decrease in Constant Score (76.00 [interquartile range 61.37-86.87] vs. 95.75 [interquartile range 91.37-98.00]; p<0.001). After three months most of the parameters seemed to have recovered, except for range of motion. Procedure-related increase in pain (i.e. NRS increase ≥1 point) was the most important independent predictor of shoulder impairment, in terms of Constant Score modification (r=0.570; p<0.001). CONCLUSIONS: ICD implantation is frequently associated with ipsilateral shoulder impairment which tends to recover within 3-months. These data positively compare with the subpectoral approach and should be considered for future research regarding impact of ICD implant on physical well-being and quality of life.
Diemberger I, Pegreffi F, Mazzotti A, Foschi E, Martignani C, Belli G, et al. (2013). Implantation of cardioverter-defibrillator: Effects on shoulder function. INTERNATIONAL JOURNAL OF CARDIOLOGY, 168(1), 294-299 [10.1016/j.ijcard.2012.09.071].
Implantation of cardioverter-defibrillator: Effects on shoulder function.
DIEMBERGER, IGOR;PEGREFFI, FRANCESCO;MAZZOTTI, ANDREA;FOSCHI, ELIA;MARTIGNANI, CRISTIAN;BELLI, GUIDO;BIFFI, MAURO;ZIACCHI, MATTEO;BRANZI, ANGELO;GRIGIONI, FRANCESCO;MAIETTA LATESSA, PASQUALINO;PORCELLINI, GIUSEPPE;TENTONI, CLAUDIO;BORIANI, GIUSEPPE
2013
Abstract
Abstract BACKGROUND: Subcutaneous almost substituted subpectoral approach of implantable cardioverter-defibrillator (ICD) implantation as a less invasive surgical technique. However, the impact of this change in placement site on procedure-related shoulder impairment is poorly understood. METHODS: Candidates for ICD implantation were prospectively evaluated at baseline, 2-weeks and 3-months after the procedure. Assessment of shoulder function included: Constant Score, Numeric Rating Scale (NRS) for pain and the Disability of the Arm, Shoulder and Hand (DASH) scoring method. The Short Form-36 (SF-36) questionnaire was adopted for quality of life. RESULTS: Fifty consecutive patients were enrolled (21 single-chamber, 5 dual-chamber and 24 biventricular ICD). Significant changes in the short term were observed: physical component summary (regarding SF-36) decreased from 44.5±9.1 to 41.8±11.4 (p=0.016), patients with NRS >1 increased from 14% to 44% (p<0.001), DASH score increased from 1.29 [interquartile range 0.00-10.34] to 30.60 [interquartile range 12.93-46.34] (p<0.001). Notably, only the shoulder ipsilateral to implantation site presented a decrease in Constant Score (76.00 [interquartile range 61.37-86.87] vs. 95.75 [interquartile range 91.37-98.00]; p<0.001). After three months most of the parameters seemed to have recovered, except for range of motion. Procedure-related increase in pain (i.e. NRS increase ≥1 point) was the most important independent predictor of shoulder impairment, in terms of Constant Score modification (r=0.570; p<0.001). CONCLUSIONS: ICD implantation is frequently associated with ipsilateral shoulder impairment which tends to recover within 3-months. These data positively compare with the subpectoral approach and should be considered for future research regarding impact of ICD implant on physical well-being and quality of life.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.